Compare lighting data, explore geometry and measurement models, plan light doses, photographic settings and strip stock, and estimate energy and costs.
Measure & convert light
Convert readings, examine measurement models and account for light exposure.
Plan repeated identical LED strip lengths from a supplied cut interval, choosing not to exceed or to reach a target, with optional matching per-metre totals.
Inputs and results
Inputs
Target length per run in m, manufacturer cut interval in mm, rounding direction, whole run count and optional matching lm/m, W/m and LEDs/m.
Results
Cut intervals and actual length per run, shortfall or excess, total cut length and optional lm, W and LED counts on the supplied strip-rating basis.
Estimate conditional screen luminance from delivered white-light output, image area and matching directional gain, or solve a supplied luminance target for delivered lumens.
Inputs and results
Inputs
Image width and height in m, directional screen gain, screen-delivered lm or area-average projector-only lx, or a target in cd/m², with matching source and model conditions.
Results
Conditional white-image cd/m² and approximate fL, average lx and screen-delivered lm; no ambient-contrast or suitability verdict.
Calculate nominal projector distance or image dimensions from a supplied matching throw-ratio range and image aspect ratio.
Inputs and results
Inputs
Manufacturer throw-ratio limits, matching image aspect ratio, image width or diagonal in m, or lens-to-screen distance in m, with the source and conditions.
Results
Nominal distance or image width, height and diagonal ranges; no mounting, focus-range or brightness verdict.
Spectrum & photometry
Analyse supplied waveforms and spectra, or look up directional IES candela.
Integrate and mix spectra, calculate conditional PPF, PPFD, PPE and chromaticity, convert CIE xy/uv/u′v′ coordinates, or explore monochromatic photon energy.
Inputs and results
Inputs
Spectral nodes or bands with their scale and coverage; existing chromaticity coordinates and observer basis; or monochromatic wavelength, photon energy or optical rate.
Results
Spectral and photopic integrals, conditional photon quantities and xy/1960 uv/1976 u′v′; or monochromatic photon energy and rates. No CCT or colour-rendering judgement.
Inspect a supported Type C IES candela grid and interpolate directional intensity within its recorded horizontal and vertical angles.
Inputs and results
Inputs
LM-63-2002 file text with TILT=NONE and unity ballast fields, plus a direction inside the stored angle range.
Results
Directional cd, interpolation brackets, recorded intensity curve and file metadata; no symmetry expansion or total-lumen integration.
Start with the task and the inputs you have
Product comparison, beam geometry and running cost answer different questions. Note where the light is needed and what you want to understand before choosing a tool.
What to bring
For product comparison, use the exact model, operating setting and data sheet. Keep light output, input watts and other attributes on the same basis.
For beam geometry, use a full circular angle and the distance to a perpendicular target plane. The output describes an ideal circle, not sufficient or even lighting.
For energy and cost, use count, operating watts, daily hours and specified days. Add a single usage rate if known; leave it blank for energy only.
Readings, power and investment
Bring a value and unit for illuminance conversion; directional candela, ray distance and incidence angle for a point-source estimate; or same-condition, equal-area readings for statistics. Power density needs input watts and matching floor area. Payback needs additional investment and full-year net savings for comparable service.
What needs a separate check
Task-surface illuminance, glare, detailed distribution, dimmer compatibility and installation conditions require information beyond these calculations. No result confirms an Australian installation or a complete lighting design.