Home Tools Lighting tools Choose by the question you need to answer. Each tool explains what to bring, what it returns and where its limits are.
Follow a task through its next steps Measure & convert light Convert readings, examine measurement models and account for light exposure.
Convert the same illuminance between lux, kilolux and foot-candles, with metric units shown first.
Inputs and results
Inputs A nonnegative illuminance and its unit: lx, klx or fc.
Results The same illuminance in lx, klx and fc. Apply your instrument’s additive reading-percentage and display-count specification to an illuminance reading.
Inputs and results
Inputs Reading in lx, percentage of reading, additional display counts, resolution in lx/count and specification conditions.
Results Additive tolerance allowance and a nonnegative specification band in lx, without a confidence claim. Estimate direct point illuminance from directional candela, add compatible sources, or scale a measured direct contribution by distance.
Inputs and results
Inputs Directional intensity in cd, source-to-point distance in m and incidence angle from the normal in degrees.
Results Direct illuminance in lx at the specified point, with model conditions. Estimate luminance from surface illuminance and luminous reflectance for an ideal non-emitting Lambertian reflector.
Inputs and results
Inputs Surface illuminance in lx and diffuse luminous reflectance as a fraction, with a Lambertian model declaration.
Results Ideal reflected luminance in cd/m²; no glare or display-brightness assessment. Calculate direct illuminance at the on-axis point facing a uniform-luminance Lambertian disc on a parallel plane.
Inputs and results
Inputs Uniform luminance in cd/m², emitting radius and axial separation in m, with the disc-model conditions.
Results Direct on-axis lx and angular half-angle; not an off-axis map or a real panel photometry substitute. Calculate the indoor-to-outdoor horizontal illuminance ratio under declared overcast daylight measurement conditions.
Inputs and results
Inputs Simultaneous indoor and unobstructed outdoor lx, with sky, plane and artificial-light conditions.
Results Daylight-factor percentage and a warning for indoor readings above the outdoor reference; no target verdict. Summarise spatial lux or PPFD samples with a supplied reference, or describe daylight occupied-time coverage with missing periods kept explicit.
Inputs and results
Inputs Same-basis spatial lux/PPFD and represented areas, or daylight-only zone/time records, occupied horizon and user threshold.
Results Spatial descriptive statistics and reference shares, or daylight area-time coverage bounds, observed mean and recorded exposure. Add lux-hours across exposure periods and compare them with your own budget, with optional remaining-time arithmetic.
Inputs and results
Inputs Lux and hours for each period; optional lx·h budget and positive future lx.
Results Accumulated lx·h, optional remaining or excess exposure, and time at the supplied future level. Plan spaces & beams Explore beam outlines, room dimensions and conditional average-light estimates.
Solve ideal circular beam geometry on a perpendicular plane, or a tilted cone’s finite ellipse. Geometry does not establish lighting adequacy.
Inputs and results
Inputs Full cone angle, axial distance or perpendicular diameter; tilted-ellipse mode also requires axis tilt from the plane normal.
Results Conditional circle geometry, or ellipse major/minor diameters, area and centre offset. Calculate rectangular area, luminaire-to-plane height and room index from dimensions measured on a common basis.
Inputs and results
Inputs Room length and width, source and working-plane heights in m, with a shared level datum.
Results Area in m², height above the working plane in m and dimensionless room index K. Find the intersection and union of two geometric circles from their diameters and centre separation.
Inputs and results
Inputs Two circle diameters and centre-to-centre separation in m, on the same plane.
Results Overlap and union in m², plus overlap as a percentage of each circle. Calculate an equal-cell grid, axis coordinates and spacing-to-height ratios. Geometry supplies no lighting adequacy verdict.
Inputs and results
Inputs Rectangle length and width in m, rows, columns and positive height above the working plane in m.
Results Point count, centres along each axis, adjacent spacing and conditional spacing-to-height ratios. Calculate solid angle and luminous flux inside an ideal circular cone with constant intensity throughout it.
Inputs and results
Inputs Full circular cone angle in degrees and constant intensity in cd, with an explicit uniform-model declaration.
Results Solid angle in sr and ideal cone flux in lm; not real total lumens from a peak-candela rating. Estimate average maintained illuminance with declared UF/MF, or use a separate supplied photon-delivery budget for average PPFD and count.
Inputs and results
Inputs Working-plane area in m², initial whole-luminaire lm, UF/MF fractions, count or target lx, and recorded assumptions.
Results Conditional average maintained lx, or a rounded-up luminaire count and its modelled average. Compare products & costs Compare specifications, prepare lighting totals and estimate energy and costs.
Compare two products and calculate luminaire efficacy, or convert lumens and input watts using a supplied matching efficacy.
Inputs and results
Inputs Product specifications; conversion requires a supplied luminaire lm/W value, known lm or W and matching-data conditions.
Results A side-by-side record and conditional lm/W; a separate conversion calculates lm or W under your supplied efficacy. Add counts, matching luminaire output and input power across groups, with separate lumen/lm-W and PPF/photon-efficacy quantities.
Inputs and results
Inputs One row per group: count, complete-luminaire lm or 400–700 nm PPF µmol/s, and whole-luminaire input W.
Results Group count, output and input totals, with combined lm/W or µmol/J and individual photon group comparisons. Multiply four supplied maintenance components on a matching basis without choosing product data or a cleaning schedule.
Inputs and results
Inputs LLMF, LSF, LMF and RSMF fractions, plus their common source, period and maintenance basis.
Results Combined maintenance factor and modelled percentage reduction from the initial level. Estimate luminaire lm and input W separately within a supplied measured control-setting curve using piecewise linear interpolation.
Inputs and results
Inputs Measured setting %, initial luminaire lm and input W rows, a setting within their range and matching system conditions.
Results Interpolated or exact-point lm, W and conditional lm/W; no extrapolation or compatibility judgement. Estimate lighting kWh and usage cost with simple comparisons, mixed operating states, or different day types and seasonal schedules.
Inputs and results
Inputs Counts, input W, non-overlapping state hours, specified days and optional usage rates; group IDs and mutually exclusive day-type counts where used.
Results Energy in kWh and conditional usage cost in AUD; simple-mode A-minus-B differences or combined state/day-type totals. Add upfront, electricity, maintenance and planned replacement costs, or compare two lighting options with a supplied real discount rate.
Inputs and results
Inputs Luminaire data, whole-year horizon, constant AUD costs and replacement plan; comparison adds an alternative, real annual discount rate and comparable-service declaration.
Results Undiscounted budget, or both options’ present cost components and a signed baseline-minus-alternative difference on the same horizon. Calculate factor-based electricity emissions and an optional baseline difference, keeping the factor source and accounting boundary explicit.
Inputs and results
Inputs Electricity kWh, supplied kg CO₂e/kWh, optional baseline kWh and the factor source, year, region, method and scopes.
Results kg and tonnes CO₂e, optional baseline and signed difference; no factor or offset claim is selected. Calculate unadjusted whole-luminaire input power per floor area from groups of lights. No NCC compliance verdict.
Inputs and results
Inputs Floor area in m² and groups with whole light counts and whole-luminaire input W.
Results Total input watts and unadjusted W/m² for the declared boundary. Estimate simple payback from additional upfront investment and full-year net savings under constant assumptions.
Inputs and results
Inputs Additional investment in AUD, annual net saving in AUD/year and a consistent comparison basis.
Results Undiscounted payback in years, or an explanation when no positive payback applies. Plan LED strips Round runs to permitted cut intervals and allocate matching reels and offcuts.
Plan repeated identical LED strip lengths from a supplied cut interval, choosing not to exceed or to reach a target, with optional matching per-metre totals.
Inputs and results
Inputs Target length per run in m, manufacturer cut interval in mm, rounding direction, whole run count and optional matching lm/m, W/m and LEDs/m.
Results Cut intervals and actual length per run, shortfall or excess, total cut length and optional lm, W and LED counts on the supplied strip-rating basis. Round varied runs to permitted cuts and allocate continuous pieces to usable leftovers and new matching reels.
Inputs and results
Inputs Run targets and counts, existing usable pieces, new reel length, manufacturer cut interval and floor or ceiling rule.
Results Per-run cut lengths, per-stock allocations, new reel count, remaining stock, unmet runs and an explicit optimisation status. Plan plant lighting Calculate daily light integral and supplemental hours for your supplied target.
Calculate baseline DLI and the supplemental light time needed for your supplied target within a limited daily window.
Inputs and results
Inputs Baseline DLI or representative PPFD/time periods, sourced target DLI, incremental supplement PPFD and available hours per day.
Results Baseline, numerical dose gap, required and planned hours, achievable total and remaining gap. Photography Work with exposure, manual flash, lighting ratios and nominal colour shifts.
Solve shutter time, aperture or ISO after an ND change, and convert cine frame rate and shutter angle to exposure time.
Inputs and results
Inputs Baseline and target camera settings, absolute ND losses or transmission stacks; optional cine fps and angle.
Results Equivalent settings, ND transmission/density, setting EV and distinctly labelled unfiltered-scene equivalent EV100. Use matching metric GN ratings to solve aperture, distance or required energy fraction, including compatible same-point flash contributions.
Inputs and results
Inputs Full-power reference GN and ISO, shooting ISO, manual energy fraction, flash-to-subject distance or f-number and rating conditions.
Results Nominal aperture, distance, effective GN or required energy fraction, with an explicit over-full-power result when applicable. Calculate key/fill or bright/dark ratios and stop differences from compatible readings, with a separate flash/ambient share mode.
Inputs and results
Inputs Two comparable linear readings or same-ISO/shutter metered f-numbers, measurement definition and conditions.
Results Named light ratio, stop difference, optional declared equal-fill bright/dark model or flash exposure share. Find the signed mired change between two CCT values or apply a supplied nominal reciprocal-temperature shift.
Inputs and results
Inputs Source and target CCT in K, or source CCT and a signed manufacturer-supplied mired shift.
Results Source and target mired, signed shift and conditional target K, without a filter or tint recommendation. Projection Relate throw distance to image size and estimate conditional screen luminance.
Estimate conditional screen luminance from delivered white-light output, image area and matching directional gain, or solve a supplied luminance target for delivered lumens.
Inputs and results
Inputs Image width and height in m, directional screen gain, screen-delivered lm or area-average projector-only lx, or a target in cd/m², with matching source and model conditions.
Results Conditional white-image cd/m² and approximate fL, average lx and screen-delivered lm; no ambient-contrast or suitability verdict. Calculate nominal projector distance or image dimensions from a supplied matching throw-ratio range and image aspect ratio.
Inputs and results
Inputs Manufacturer throw-ratio limits, matching image aspect ratio, image width or diagonal in m, or lens-to-screen distance in m, with the source and conditions.
Results Nominal distance or image width, height and diagonal ranges; no mounting, focus-range or brightness verdict. Spectrum & photometry Analyse supplied waveforms and spectra, or look up directional IES candela.
Calculate time-weighted mean, percent modulation and flicker index from a complete-cycle linear optical waveform.
Inputs and results
Inputs Nonnegative equal-duration optical samples, or constant levels with positive durations, and their measurement conditions.
Results Sampled extrema, time-weighted mean, percent modulation and flicker index; no health or camera-banding rating. Integrate and mix spectra, calculate conditional PPF, PPFD, PPE and chromaticity, convert CIE xy/uv/u′v′ coordinates, or explore monochromatic photon energy.
Inputs and results
Inputs Spectral nodes or bands with their scale and coverage; existing chromaticity coordinates and observer basis; or monochromatic wavelength, photon energy or optical rate.
Results Spectral and photopic integrals, conditional photon quantities and xy/1960 uv/1976 u′v′; or monochromatic photon energy and rates. No CCT or colour-rendering judgement. Inspect a supported Type C IES candela grid and interpolate directional intensity within its recorded horizontal and vertical angles.
Inputs and results
Inputs LM-63-2002 file text with TILT=NONE and unity ballast fields, plus a direction inside the stored angle range.
Results Directional cd, interpolation brackets, recorded intensity curve and file metadata; no symmetry expansion or total-lumen integration. No tools match your search. Try “lumens”, or clear the search to see all tools.