Illuminance Unit Converter

Convert the same illuminance between lux, kilolux and foot-candles, with metric units shown first.

Express the same illuminance in lux, kilolux and foot-candles. This is a unit conversion, not a conversion from lumens or a lighting recommendation.

Results update as you edit.

Calculating needs JavaScript. The form becomes available when its script is ready; the guide below is always readable.

Calculation inputs

Calculation inputs
A finite decimal of zero or more. Use a decimal point, without thousands separators.
Changing this unit converts a valid entered amount to preserve the same illuminance. All three units are shown in the result.

Continue your task

Carry unrounded converted lx with the original reading, plane and conditions.

If this answers your question within the model’s limits, record the original inputs, unrounded result and conditions. Otherwise choose an action only when its condition applies:

See this task in the decision tree

Opening another tool does not transfer or store your entries. Keep the original values, units and conditions with the next calculation.

Lux and foot-candles describe the same quantity

Illuminance describes light arriving at a surface per unit area. Lux (lx) is lumen per square metre; a foot-candle (fc) uses a square foot instead. The larger numerical lux value does not mean a brighter measurement: it is the same illuminance expressed with a different area unit. Kilolux (klx) is simply 1,000 lux.

The NIST conversion table gives approximately 10.76391 lux per foot-candle. The exact international foot is 0.3048 metre, so a square foot is exactly 0.09290304 m². This gives:

  • fc = lx × 0.09290304
  • lx = fc ÷ 0.09290304
  • klx = lx ÷ 1,000

The calculator retains the factor’s precision during calculation and rounds only the displayed result. Lux and foot-candles display to two decimal places; kilolux displays to four. A positive value below the smallest displayed increment appears with a less-than sign rather than as zero.

A converted reading keeps its original context

For an artificial example, 500 lx = 0.5000 klx = 46.45 fc after display rounding. Starting with 1 fc gives approximately 10.76 lx. Neither direction changes where the reading was taken, the meter’s accuracy or the lighting conditions.

Keep the measurement plane and operating conditions with the value when comparing readings. A reading on a floor and one on a kitchen bench remain different observations even after both are expressed in lux. A unit conversion cannot establish a suitable light level for either task.

Why lumens need a different calculation

Lumens describe luminous flux, while lux describes flux arriving per area. A total product lumen rating therefore cannot be converted to lux by changing a unit label. Geometry, distribution and the receiving surface matter. Where directional candela and point-source conditions are available, the point-source illuminance tool estimates direct light at a specified point; it does not turn a lumen label into a room-wide measurement.

Related tools

Point-source Illuminance

Estimate direct point illuminance from directional candela, add compatible sources, or scale a measured direct contribution by distance.

Inputs and results
Inputs
Directional intensity in cd, source-to-point distance in m and incidence angle from the normal in degrees.
Results
Direct illuminance in lx at the specified point, with model conditions.

Illuminance Sample Statistics

Summarise spatial lux or PPFD samples with a supplied reference, or describe daylight occupied-time coverage with missing periods kept explicit.

Inputs and results
Inputs
Same-basis spatial lux/PPFD and represented areas, or daylight-only zone/time records, occupied horizon and user threshold.
Results
Spatial descriptive statistics and reference shares, or daylight area-time coverage bounds, observed mean and recorded exposure.

Browse all lighting tools