Point-source Illuminance

Estimate direct point illuminance from directional candela, add compatible sources, or scale a measured direct contribution by distance.

Estimate direct illuminance at one point from intensity in that direction, source-to-point distance and the angle of incidence. Use a source that can be treated as a point at this distance.

Results update as you edit.

Calculating needs JavaScript. The form becomes available when its script is ready; the guide below is always readable.

Calculation inputs

Calculation inputs
Choose directional-candela calculation or scale a measured direct contribution under unchanged point-source conditions.
Nonnegative direct contribution of a single source at the original distance; remove ambient and reflected contributions first.
Positive distance on a ray with the same directional output and incidence angle as the new position.
Positive distance. The source setting, direction and incidence angle must remain unchanged; source size must permit point-source scaling.
Use directional candela for the actual ray, not total lumens or peak candela for a different direction. Zero is valid.
Straight-line distance from the photometric source to the point, greater than zero. This may differ from vertical mounting height.
0° means the ray is perpendicular to the surface. Use 0° ≤ angle < 90°. This is not the beam angle.
1–100 comma-separated rows at the same receiving point and plane. Use each ray’s direction, distance and angle; do not add values at different locations.
For each finite luminaire, check the applicable photometric far-field conditions. Nearby strips and large luminous panels may not fit this model.

Continue your task

Keep contributions and geometry with the direct lx result. Unmodelled reflections, daylight and other sources remain separate.

If this answers your question within the model’s limits, record the original inputs, unrounded result and conditions. Otherwise choose an action only when its condition applies:

See this task in the decision tree

Opening another tool does not transfer or store your entries. Keep the original values, units and conditions with the next calculation.

Scale a measured direct contribution by distance

When a single source behaves as a point, its directional output and receiving incidence angle stay fixed, and reflected or ambient light has been excluded, a compatible measured contribution can be scaled without first inferring candela:

E₂ = E₁(r₁/r₂)², with signed distance loss 2 log₂(r₂/r₁) stops. Positive loss means less direct light at the new distance; negative loss means a gain. Moving the receiver can change its angle or expose a different part of the beam, so those conditions must be checked separately.

For an artificial 800 lx direct contribution at 2 m, moving to 4 m on the same basis gives 800 × (2/4)² = 200.00 lx, a 2.0000-stop loss. The formula also scales a measured zero to zero, but that observation does not validate the point-source approximation. Nearby panels, strips, reflections and a total room reading generally do not fit this single-contribution model.

Directional intensity is the starting point

This estimate answers a specific question: how much direct illuminance does one point-like source contribute at one receiving point? The source’s luminous intensity must be known in the direction of that point, in candela (cd). A product’s total lumens do not supply that directional value. Peak candela is usable only when the receiving point lies in the direction to which that peak applies.

For an unobstructed ray, the model is E = I × cos α ÷ r², where E is illuminance in lux, I is the directional intensity in candela, r is the straight-line source-to-point distance in metres, and α is the angle between the incident ray and the surface normal. The normal is an imaginary line perpendicular to the receiving surface.

The inverse-square relationship spreads the source contribution with distance. The cosine projection accounts for the receiving surface being tilted relative to the ray. That reference discusses radiometric irradiance; the area projection also applies to photometric flux, without converting watts into lux.

If you have a supported manufacturer file, IES Candela Lookup can read or interpolate intensity inside its recorded angle range. Match the file coordinates to the installed luminaire and receiving point before using the value here.

Distance and tilt affect the result differently

These artificial cases hold directional intensity at 1,600 cd. Each case assumes the point-source model is appropriate and the path is unobstructed.

Source-to-point distance Incidence angle from normal Direct illuminance
4 m 0° 100.00 lx
8 m 0° 25.00 lx
4 m 60° 50.00 lx

Doubling distance quarters the contribution because distance is squared. Tilting the receiving surface to 60° halves it because cos 60° = 0.5. Display values round to two decimal places; the calculation uses unrounded values.

For a point directly below a light above a horizontal bench, r can equal the vertical source-to-bench distance. For an offset point, r is the sloping distance. If moving that point also changes the ray through the luminaire’s distribution, use the candela for the new direction rather than holding peak intensity constant.

Incidence angle is not beam angle

At 0° incidence, the ray strikes squarely onto the surface. As incidence approaches 90°, the projected contribution approaches zero. The supported range stops below 90°; a ray striking the back of a surface belongs to a different geometry. A manufacturer’s full beam angle describes its distribution and must not be entered as this incidence angle. The beam geometry tool handles an ideal angle-defined circular outline separately.

Add direct contributions at the same receiving point

Multiple-source mode evaluates Σ Iᵢ cos αᵢ/rᵢ². Each row needs its own directional intensity, ray distance and incidence angle, all referring to the same point and receiving plane. Adding values at different locations would not describe the illuminance at either location.

For an artificial pair with normal incidence and 4 m ray distances, 1,600 cd contributes 100 lx and 800 cd contributes 50 lx, giving 150.00 lx. If the second ray instead arrives at 60° from the normal, its contribution is 25 lx and the sum is 125.00 lx. The first contribution does not change. This sum includes no reflected or daylight contribution unless separately represented by a model that actually supports it.

Where a point-source estimate stops being useful

A real luminaire has size. At distances where that size and its near-field distribution matter, a single point with directional intensity may be inadequate. A nearby luminous panel or strip needs an appropriate extended-source method or applicable photometric data; increasing the number of decimal places does not fix the model.

The result includes this source’s direct contribution only. Other lights, daylight, reflections and obstructions can change measured illuminance. It does not establish uniformity across the surface, glare, maintained lighting or compliance. To summarise suitably collected readings from an actual surface, use equal-area illuminance sample statistics.

Related tools

Beam Spread Geometry

Solve ideal circular beam geometry on a perpendicular plane, or a tilted cone’s finite ellipse. Geometry does not establish lighting adequacy.

Inputs and results
Inputs
Full cone angle, axial distance or perpendicular diameter; tilted-ellipse mode also requires axis tilt from the plane normal.
Results
Conditional circle geometry, or ellipse major/minor diameters, area and centre offset.

Uniform Cone Luminous Flux

Calculate solid angle and luminous flux inside an ideal circular cone with constant intensity throughout it.

Inputs and results
Inputs
Full circular cone angle in degrees and constant intensity in cd, with an explicit uniform-model declaration.
Results
Solid angle in sr and ideal cone flux in lm; not real total lumens from a peak-candela rating.

Illuminance Unit Converter

Convert the same illuminance between lux, kilolux and foot-candles, with metric units shown first.

Inputs and results
Inputs
A nonnegative illuminance and its unit: lx, klx or fc.
Results
The same illuminance in lx, klx and fc.

Illuminance Sample Statistics

Summarise spatial lux or PPFD samples with a supplied reference, or describe daylight occupied-time coverage with missing periods kept explicit.

Inputs and results
Inputs
Same-basis spatial lux/PPFD and represented areas, or daylight-only zone/time records, occupied horizon and user threshold.
Results
Spatial descriptive statistics and reference shares, or daylight area-time coverage bounds, observed mean and recorded exposure.

Browse all lighting tools