Flux within a cone depends on its solid angle
Luminous intensity in candela describes luminous flux per solid angle in a direction. If that intensity is constant throughout a specified cone, its flux is lumens = candela × steradians. The RP Photonics explanation of luminous intensity describes this directional quantity and uniform emission.
A solid angle describes a portion of the directions around a point, rather than an area on a bench. MathWorld defines it using the area on a unit sphere and gives the spherical-coordinate integral. Integrating over all directions within a circular cone gives Ω = 2π[1 − cos(θ/2)], where θ is the full cone angle. This tool supports θ greater than 0° and no more than 180°; at 180° the cone covers a hemisphere, with solid angle 2π sr.
Distance does not enter this calculation. Moving a receiving plane farther away spreads the same cone flux over a different area; it does not change how many directions the cone covers. The beam geometry calculator separately explores an angle-defined circle at a specified distance.
An ideal 120° cone at 100 cd
For an artificial uniform model, let the full cone angle be 120° and intensity be 100 cd in every direction inside it. The half-angle is 60°, and cos 60° = 0.5:
Ω = 2π(1 − 0.5) = π sr.
Cone flux = 100π lm = 314.16 lm, rounded to two decimal places. The displayed solid angle is 3.1416 sr; that display rounding is not used to compute the flux.
Widening the cone while holding intensity fixed increases the flux because more directions carry that intensity. Flux is not proportional to the angle in degrees. Holding angle fixed and doubling the constant intensity does double the cone flux.
Why a real beam angle and peak candela are insufficient
A real luminaire usually has a varying intensity distribution. Its peak candela describes one direction, while its stated beam angle describes a boundary under the manufacturer’s angle convention. It does not establish constant intensity across the cone, nor zero output outside it. Multiplying that peak by the calculated solid angle therefore does not recover measured total lumens.
This result is the flux inside the ideal cone. It equals the ideal source’s total output only if no light is emitted outside that cone. Real total flux requires integration of the applicable distribution or suitable measured data. To estimate direct illuminance at one point using a known intensity in that specific direction, use point-source illuminance with its distance, incidence-angle and point-source conditions.