Lighting tasks, from inputs to next steps

Choose the question, check the inputs and follow only the branch that fits. The decision tree includes result uses, feedback paths and points where more information is needed.

Open the task decision tree

Choose a task and follow its conditions

Start with the question you need to answer. Open a branch, check its required data and use only the calculations whose assumptions fit. You can enter at any tool; completing every branch is unnecessary.

If a valid result answers your question within its stated limits, finish by recording the original inputs, unrounded result and conditions. Revisit the relevant branch when the product, layout, measurements or operating schedule changes.

When the calculation is not the next step

  • Obtain the missing source data

    Request the exact product, instrument, factor or method data named in the branch. Keep its units, setting, date and conditions; do not substitute an unrelated default.

  • Use project-specific lighting design

    Bring actual photometry, room and surface information, task plane, layout and project requirements to a suitable lighting professional. These arithmetic tools do not assess glare, full distributions or compliance.

  • Check the applicable electrical or regulatory method

    For electrical selection use a licensed electrical professional with the actual load and installation data. For an NCC assessment establish the jurisdiction, edition, building scope and applicable method; unadjusted watts alone are insufficient.

  • Review the measurement basis before deciding

    Check instrument range and calibration, representative locations, plane, time, daylight and operating conditions. Resolve differences against the relevant measurement method and project requirements before changing a design factor or declaring a pass.

  • Resolve the comparison or budget basis

    Collect a consistent full-year schedule, applicable tariff and relevant project costs; check comparable lighting service separately. Use a suitable financial method if discounting, escalation or uncertainty is material.

  • Obtain an object-specific conservation basis

    Ask a suitable conservator for the object’s sensitivity, budget period and display conditions. Do not infer a safe limit from the lux-hour arithmetic.

Links open separate tools without transferring or storing entries. Keep the original values, units and conditions. A feedback link means reviewing the original basis, not changing a factor solely to match a desired result.

Related task examples

These groups collect related calculations for reference. They are optional branches, not a required sequence; use the decision tree above to check each calculation’s conditions.

Prepare and explore a lighting plan

How do product data, room dimensions, a maintained average and a coordinate sketch fit together?

An average and a grid do not establish point illuminance, glare, uniformity or installation compliance. Actual photometry and project requirements remain necessary.

Check and interpret illuminance readings

What do the recorded readings represent, and how do they compare with a conditional model?

A sample statistic cannot validate a measurement grid, meter calibration or standards compliance. Keep the plane, time, daylight and operating conditions with the readings.

Budget and compare lighting operation

How much power and energy does the declared schedule use, and what does a supplied saving imply for payback?

Lower electricity use does not establish equivalent lighting service. Match the comparison period, tariff and cost basis, and check the service independently.

Separate beam geometry from light quantities

Which calculation describes an outline, an ideal flux distribution or direct illuminance at one point?

Do not turn a beam angle and peak candela into real total lumens or room lux. Each model requires its own declared distribution and geometry.

Account for an object’s light exposure

How much illuminance-time exposure has one object received, and what remains within a supplied budget?

An exposure budget must suit the object and period. Lux-hours do not predict damage, and the calculator chooses no conservation limit.

An artificial project across the tools

This example connects the arithmetic; its product data, factors, target and prices are invented assumptions. It is not a recommended lighting design. Comparable lighting service is assumed to have been checked separately.

Task and inputsIndependently calculated resultWhat to keep
10 × 5 m rectangle; source 3 m and plane 1 m above one datum50 m²; h = 2 m; K = 5/3The actual geometry and reference plane
LLMF .9, LSF 1, LMF .8, RSMF .95MF = .684The common maintenance plan; these are artificial factors
3,000 initial lm per luminaire, UF .6, MF .684, supplied target 350 lxceil(17,500/1,231.2) = 15 luminaires; modelled average 369.36 lxInitial output and explicit factor basis; 350 lx is not a recommendation
3 rows × 5 columns in that rectangle15 grid points; x spacing 2 m, y spacing 5/3 mA geometric sketch, subject to a new distribution check
15 luminaires, 3,000 initial lm and 20 W each45,000 lm, 300 W; 6 W/m² over 50 m²Whole-luminaire input, including required drivers
15 × 20 W × 5 h/day × 300 operating days/year at AUD.30/kWh450 kWh/year; AUD135/year in usage costThe remaining days have zero use in this artificial schedule; no standby cost is assumed
Baseline: 20 × 25 W, same hours/days and rate; additional investment AUD360Baseline 750 kWh and AUD225/year; net annual saving AUD90; simple payback 4 yearsComparable service and no other net annual cost differences are explicit assumptions

After a change, readings such as an artificial 340, 360 and 380 lx have a sample mean of 360 lx. That does not prove a 350 lx target is met at every location or identify why the model and readings differ. Check measurement conditions and representativeness before changing the design assumptions.

Keep the basis with the number

These are linked tasks, not an automated design or product-selection service. Entries remain in each calculator; opening another tool does not transfer or store them. Carry the unrounded source values, units and conditions yourself, then check that the next model accepts that basis.

After installation or a change in operating conditions, compare new measurements with the original assumptions. A difference can reflect distribution, daylight, maintenance, instrument limitations or a different measurement plane; changing a coefficient solely to match the reading does not explain the cause.

Browse every calculator or read how inputs and results are handled.