Lighting tasks, from inputs to next steps
Choose the question, check the inputs and follow only the branch that fits. The decision tree includes result uses, feedback paths and points where more information is needed.
Choose a task and follow its conditions
Start with the question you need to answer. Open a branch, check its required data and use only the calculations whose assumptions fit. You can enter at any tool; completing every branch is unnecessary.
If a valid result answers your question within its stated limits, finish by recording the original inputs, unrounded result and conditions. Revisit the relevant branch when the product, layout, measurements or operating schedule changes.
Collect and compare product data
Do I have comparable output and power data for the exact products and settings?
A higher lm/W value does not establish suitable distribution, colour quality, control compatibility or equivalent lighting service.
Compare two specified luminaires, or calculate lm or W from a supplied matching efficacy.
- Before using it
- Keep the exact model, driver, setting and whole-luminaire data basis; conversion also needs a supplied lm/W value for those same conditions.
- Inputs and units
- Product specifications; conversion requires a supplied luminaire lm/W value, known lm or W and matching-data conditions.
- Result
- A side-by-side record and conditional lm/W; a separate conversion calculates lm or W under your supplied efficacy.
- Use the result
- Request missing data from the comparison record. Keep values calculated from supplied efficacy labelled as calculations, separate from manufacturer specifications.
Choose the next action only when its condition applies:
A required dimming setting lies between supplied measured points for the same system.
Continue: Measured Dimming Curve InterpolationThe chosen groups have matching output and input-power data.
Continue: Lighting Schedule TotalsData is missing, uses source lumens or describes a different setting.
Pause: Obtain the missing source data
Estimate lm and input W at a setting inside a measured dimming curve.
Measured Dimming Curve Interpolation
- Before using it
- Supply measured setting/lm/W rows from the same luminaire, driver, control and test conditions; the requested setting must be within their range.
- Inputs and units
- Measured setting %, initial luminaire lm and input W rows, a setting within their range and matching system conditions.
- Result
- Interpolated or exact-point lm, W and conditional lm/W; no extrapolation or compatibility judgement.
- Use the result
- Keep the estimated lm and W as a pair. A control percentage is not automatically the same percentage of output or input power.
Choose the next action only when its condition applies:
The interpolated setting is the declared operating basis for a group.
Continue: Lighting Schedule TotalsA changed setting alters the product comparison.
Revisit: Lighting Product ComparisonNo matching curve exists or the setting requires extrapolation.
Pause: Obtain the missing source data
Inspect a supported IES file and query directional candela inside its recorded angle range.
- Before using it
- Supply LM-63-2002 Type C data with TILT=NONE and unity ballast fields; identify the matching product, operating state and photometric coordinates.
- Inputs and units
- LM-63-2002 file text with TILT=NONE and unity ballast fields, plus a direction inside the stored angle range.
- Result
- Directional cd, interpolation brackets, recorded intensity curve and file metadata; no symmetry expansion or total-lumen integration.
- Use the result
- Keep the file identity, requested angles, multiplier and sample/interpolation status with the intensity. Stored angles are not automatically room directions.
Choose the next action only when its condition applies:
The queried direction matches the receiving point and actual luminaire orientation, with an appropriate point-source model.
Continue: Point-source IlluminanceThe file is unsupported, the direction is outside the stored range, or a complete distribution simulation is needed.
Pause: Use project-specific lighting design
Summarise the counts, initial output and input power of mixed luminaire groups.
- Before using it
- Use complete-luminaire lm and input W at matching settings, with a whole count for each group.
- Inputs and units
- One row per group: count, complete-luminaire lm or 400–700 nm PPF µmol/s, and whole-luminaire input W.
- Result
- Group count, output and input totals, with combined lm/W or µmol/J and individual photon group comparisons.
- Use the result
- Keep group-level data as well as totals: different operating hours cannot be recovered from one combined wattage.
Choose the next action only when its condition applies:
The floor-area boundary matches the scheduled groups.
Continue: Lighting Power DensityOperating hours, standby states and any usage rates are available.
Continue: Lighting Energy and Running CostThe question is which product or circuit is safe to install.
Pause: Check the applicable electrical or regulatory method
Prepare a space and geometric sketch
Which dimensions and geometric quantities does my next calculation actually need?
Circle outlines, overlap and grid coordinates do not establish illuminance, uniformity, glare or a compliant layout.
Relate a supplied projector throw-ratio range to a rectangular image and nominal distance.
Projector Throw Distance and Image Size
- Before using it
- Use one model, lens and image mode, matching full-image aspect ratio and the manufacturer’s distance reference. Supply image width or diagonal, or lens-to-screen distance, in m.
- Inputs and units
- Manufacturer throw-ratio limits, matching image aspect ratio, image width or diagonal in m, or lens-to-screen distance in m, with the source and conditions.
- Result
- Nominal distance or image width, height and diagonal ranges; no mounting, focus-range or brightness verdict.
- Use the result
- Keep the ratio source and image mode with both range endpoints. Compare the nominal geometry with the model-specific distance table and test the actual equipment before permanent positioning.
Choose the next action only when its condition applies:
Image dimensions, screen-delivered white-light output and matching directional screen gain are independently available for a uniform model.
Continue: Projector Screen Brightness CalculatorThe ratio, distance reference or matching image mode is unknown, or the setup uses ultra-short-throw, digital correction or other unsupported geometry.
Pause: Obtain the missing source dataMounting, clearances, focus range, screen brightness or installation suitability must be established.
Pause: Use project-specific lighting design
Prepare a rectangular working-plane area, height and room index.
Room Index and Working-plane Geometry
- Before using it
- Measure length, width and source/working-plane heights in m using a common height datum.
- Inputs and units
- Room length and width, source and working-plane heights in m, with a shared level datum.
- Result
- Area in m², height above the working plane in m and dimensionless room index K.
- Use the result
- Carry unrounded area and height; use K only with a compatible utilisation-factor method, not as a lookup that chooses UF by itself.
Choose the next action only when its condition applies:
Matching maintenance components need combining for the same plan.
Continue: Maintenance Factor CompositionMatching initial output, UF, MF and a declared target or count are already available.
Continue: Lumen Method EstimateOnly equal-cell point coordinates are needed.
Continue: Rectangular Lighting Grid GeometryA suitable utilisation method or its required data is unavailable.
Pause: Obtain the missing source data
Solve a perpendicular circular beam outline or a tilted cone’s finite ellipse.
- Before using it
- Confirm a symmetric circular cone and the manufacturer’s full-angle definition. For a perpendicular plane, supply two known quantities; for an ellipse, supply full angle, axial distance and tilt from the plane normal, with half-angle plus tilt below 90°.
- Inputs and units
- Full cone angle, axial distance or perpendicular diameter; tilted-ellipse mode also requires axis tilt from the plane normal.
- Result
- Conditional circle geometry, or ellipse major/minor diameters, area and centre offset.
- Use the result
- Use the solved dimensions as an outline, not as a boundary of uniform brightness.
Choose the next action only when its condition applies:
Two compatible circles on the same plane need comparing.
Continue: Circular Beam Overlap GeometryThe question is whether the area receives enough light.
Pause: Use project-specific lighting design
Find the intersection and union of two circle outlines.
Circular Beam Overlap Geometry
- Before using it
- Use diameters and centre separation in m on the same plane; real tilted or asymmetric footprints need another model.
- Inputs and units
- Two circle diameters and centre-to-centre separation in m, on the same plane.
- Result
- Overlap and union in m², plus overlap as a percentage of each circle.
- Use the result
- Compare shared geometric area. Overlap percentages do not describe added lux or minimum-to-mean illuminance.
Choose the next action only when its condition applies:
The source distance or angle needs changing before recalculating the outlines.
Revisit: Beam Spread GeometryAn illuminance map or layout adequacy decision is needed.
Pause: Use project-specific lighting design
Place a chosen number of rows and columns at equal-cell centres.
Rectangular Lighting Grid Geometry
- Before using it
- Use rectangle dimensions, whole rows/columns and positive source-to-working-plane height. A sampling grid must have its own measurement-method basis.
- Inputs and units
- Rectangle length and width in m, rows, columns and positive height above the working plane in m.
- Result
- Point count, centres along each axis, adjacent spacing and conditional spacing-to-height ratios.
- Use the result
- Record coordinates, point count and spacing-to-height ratios for a geometric sketch; a ratio has no automatic pass threshold.
Choose the next action only when its condition applies:
The count or layout change affects the declared utilisation assumptions.
Revisit: Lumen Method EstimateActual readings have been collected using an independently justified representative-area method.
Continue: Illuminance Sample StatisticsA proposed arrangement needs real photometry or standards assessment.
Pause: Use project-specific lighting design
Fit repeated identical LED strip runs to manufacturer-permitted cut intervals.
- Before using it
- Supply the target in m and product-specific repeated cut interval in mm from a permitted starting point. Optional lm/m and W/m must identify the exact strip, setting and rating boundary.
- Inputs and units
- Target length per run in m, manufacturer cut interval in mm, rounding direction, whole run count and optional matching lm/m, W/m and LEDs/m.
- Result
- Cut intervals and actual length per run, shortfall or excess, total cut length and optional lm, W and LED counts on the supplied strip-rating basis.
- Use the result
- Choose a length below or above the target and retain the per-run shortfall or excess. Optional strip totals do not include inferred driver losses, connectors or fitted diffuser losses.
Choose the next action only when its condition applies:
Actual complete-system input W, including required driver and control input, is independently established along with its operating schedule.
Continue: Lighting Energy and Running CostPermitted cut positions, maximum run length or the relevant product data are unavailable.
Pause: Obtain the missing source dataA power supply, cable, voltage-drop or circuit selection is needed.
Pause: Check the applicable electrical or regulatory method
Combine four supplied maintenance components on one declared plan.
Maintenance Factor Composition
- Before using it
- Supply LLMF, LSF, LMF and RSMF with matching source, period, cleaning and replacement assumptions; do not count the same loss twice.
- Inputs and units
- LLMF, LSF, LMF and RSMF fractions, plus their common source, period and maintenance basis.
- Result
- Combined maintenance factor and modelled percentage reduction from the initial level.
- Use the result
- Carry the unrounded combined MF and its maintenance basis into the matching maintained-average calculation.
Choose the next action only when its condition applies:
The remaining initial-output, area and UF inputs use the same basis.
Continue: Lumen Method EstimateComponents or their common maintenance basis are missing.
Pause: Obtain the missing source data
Choose a compatible light model
Do I need a maintained average, ideal cone flux, direct point lx, reflected luminance, projected white-image luminance or a finite-disc result?
These are alternative models. Complete only the branch whose input data and physical assumptions fit; they are not a required sequence.
Estimate a maintained average, or an arithmetic luminaire count for a supplied target.
- Before using it
- Use matching working-plane area, initial complete-luminaire lm, luminaire-based UF and MF, plus a declared count or target basis.
- Inputs and units
- Working-plane area in m², initial whole-luminaire lm, UF/MF fractions, count or target lx, and recorded assumptions.
- Result
- Conditional average maintained lx, or a rounded-up luminaire count and its modelled average.
- Use the result
- Treat a rounded-up count as an arithmetic proposal; keep the unrounded factors and check distribution and layout separately.
Choose the next action only when its condition applies:
A candidate count is ready for a geometric rows/columns sketch.
Continue: Rectangular Lighting Grid GeometryA different maintenance plan is proposed.
Revisit: Maintenance Factor CompositionPoint levels, glare, uniformity or a compliance decision are required.
Pause: Use project-specific lighting design
Explore flux inside an ideal constant-intensity circular cone.
- Before using it
- Supply a full cone angle and intensity that is constant throughout that cone. Peak candela plus a real beam angle is insufficient.
- Inputs and units
- Full circular cone angle in degrees and constant intensity in cd, with an explicit uniform-model declaration.
- Result
- Solid angle in sr and ideal cone flux in lm; not real total lumens from a peak-candela rating.
- Use the result
- Interpret sr and lm within the declared cone; this is total model output only if there is no light outside it.
Choose the next action only when its condition applies:
Real total lumens or a real distribution is needed.
Pause: Obtain the missing source data
Estimate one or several direct point-source contributions at the same receiving point.
- Before using it
- For every contribution use directional cd towards that point, actual ray distance and incidence angle from the receiving-plane normal; confirm point-source conditions.
- Inputs and units
- Directional intensity in cd, source-to-point distance in m and incidence angle from the normal in degrees.
- Result
- Direct illuminance in lx at the specified point, with model conditions.
- Use the result
- Keep contributions and geometry with the direct lx result. Unmodelled reflections, daylight and other sources remain separate.
Choose the next action only when its condition applies:
The same surface’s total incident lx is independently known and an ideal diffuse reflection model fits.
Continue: Diffuse Surface LuminanceCompatible measurements need examining before comparing them with the model.
Revisit: Illuminance Sample StatisticsSource size, distribution or geometry does not support the point-source approximation.
Pause: Use project-specific lighting design
Estimate the luminance of an ideal non-emitting Lambertian reflector.
- Before using it
- Supply incident surface lx and matching diffuse luminous reflectance, and confirm the matte-reflector assumptions.
- Inputs and units
- Surface illuminance in lx and diffuse luminous reflectance as a fraction, with a Lambertian model declaration.
- Result
- Ideal reflected luminance in cd/m²; no glare or display-brightness assessment.
- Use the result
- Interpret cd/m² for that ideal surface. Gloss, emitted light and glare assessment require other information.
Choose the next action only when its condition applies:
A real surface, display brightness or glare judgement is required.
Pause: Use project-specific lighting design
Budget a full-white projected image’s conditional luminance or the screen-delivered flux for a supplied target.
Projector Screen Brightness Calculator
- Before using it
- Use a flat front-projection rectangle, screen-delivered full-white lm or representative area-average projector-only lx, and gain for the declared illumination/viewing direction normalised to a unit-reflectance Lambertian reference. Declare uniformly applied gain and matching conditions.
- Inputs and units
- Image width and height in m, directional screen gain, screen-delivered lm or area-average projector-only lx, or a target in cd/m², with matching source and model conditions.
- Result
- Conditional white-image cd/m² and approximate fL, average lx and screen-delivered lm; no ambient-contrast or suitability verdict.
- Use the result
- Keep the output, image area, directional gain, source and conditions together. The uniform-model value is not a real screen map, centre reading or ambient-contrast result; the reverse target must be independently justified.
Choose the next action only when its condition applies:
A different complete image size needs relating to matching manufacturer throw-ratio data.
Revisit: Projector Throw Distance and Image SizeApplicable gain, delivered output or a representative average is missing.
Pause: Obtain the missing source dataReal uniformity, ambient contrast, ALR behaviour or suitability must be established.
Pause: Use project-specific lighting design
Estimate direct on-axis lx from a uniform-luminance Lambertian disc.
Uniform Disc On-axis Illuminance
- Before using it
- Supply uniform disc luminance, emitting radius and axial separation; the receiving plane must be parallel and its point on axis.
- Inputs and units
- Uniform luminance in cd/m², emitting radius and axial separation in m, with the disc-model conditions.
- Result
- Direct on-axis lx and angular half-angle; not an off-axis map or a real panel photometry substitute.
- Use the result
- Use the result for the specified finite-source geometry. A real rectangular panel or an off-axis point needs a different model.
Choose the next action only when its condition applies:
The real source or receiving geometry differs from the disc assumptions.
Pause: Use project-specific lighting design
Check and interpret measurements
What quantity, plane and conditions do my readings represent?
Neither conversion nor statistics validates calibration, a sampling plan or compliance. Keep the original readings and measurement conditions.
Express the same illuminance in lx, klx and fc.
- Before using it
- Identify the original illuminance unit; a lumen, candela or luminance value cannot be relabelled as lx.
- Inputs and units
- A nonnegative illuminance and its unit: lx, klx or fc.
- Result
- The same illuminance in lx, klx and fc.
- Use the result
- Carry unrounded converted lx with the original reading, plane and conditions.
Choose the next action only when its condition applies:
A matching additive instrument specification needs applying.
Continue: Illuminance Meter Specification RangeSeveral representative readings share a compatible measurement basis.
Continue: Illuminance Sample StatisticsObject-surface readings have known exposure durations.
Continue: Light Exposure BudgetThe source quantity or unit cannot be identified.
Pause: Obtain the missing source data
Apply an instrument’s additive percentage-plus-display-count specification.
Illuminance Meter Specification Range
- Before using it
- Supply the reading, applicable percentage, additional counts, range resolution in lx/count and specification conditions.
- Inputs and units
- Reading in lx, percentage of reading, additional display counts, resolution in lx/count and specification conditions.
- Result
- Additive tolerance allowance and a nonnegative specification band in lx, without a confidence claim.
- Use the result
- Keep the specification band as an instrument allowance; do not interpret it as a confidence interval or complete uncertainty budget.
Choose the next action only when its condition applies:
Representative readings and their area basis are ready for a descriptive summary.
Continue: Illuminance Sample StatisticsThe meter has another specification model or its applicable range is unknown.
Pause: Obtain the missing source data
Summarise equal-area or supplied area-weighted measurements.
- Before using it
- Use readings from the same plane and conditions; representative areas must be non-overlapping and have a justified basis.
- Inputs and units
- Same-basis spatial lux/PPFD and represented areas, or daylight-only zone/time records, occupied horizon and user threshold.
- Result
- Spatial descriptive statistics and reference shares, or daylight area-time coverage bounds, observed mean and recorded exposure.
- Use the result
- Retain the individual readings, minimum, mean and area basis. The sample minimum-to-mean ratio does not certify a full space.
Choose the next action only when its condition applies:
A difference from a conditional maintained-average estimate needs investigating.
Revisit: Lumen Method EstimateReadings differ from expectations or a target verdict is needed.
Pause: Review the measurement basis before deciding
Calculate an indoor/outdoor daylight ratio from a compatible paired observation.
- Before using it
- Use simultaneous horizontal indoor and unobstructed outdoor lx under the declared overcast sky, without an artificial-light contribution.
- Inputs and units
- Simultaneous indoor and unobstructed outdoor lx, with sky, plane and artificial-light conditions.
- Result
- Daylight-factor percentage and a warning for indoor readings above the outdoor reference; no target verdict.
- Use the result
- Keep the percentage with its paired readings and conditions. An indoor reading above the outdoor reference needs investigation, not a target verdict.
Choose the next action only when its condition applies:
The measurements are unpaired, conditions conflict or a building-performance decision is required.
Pause: Review the measurement basis before deciding
Budget power, operation and cost
Which operating states and cost boundaries are being compared?
Check equivalent lighting service independently. A lower cost, W/m² or emissions estimate is not evidence of suitable lighting.
Calculate unadjusted input power per declared floor area.
- Before using it
- Use the same floor boundary and complete-luminaire input W, including required drivers, for every included group.
- Inputs and units
- Floor area in m² and groups with whole light counts and whole-luminaire input W.
- Result
- Total input watts and unadjusted W/m² for the declared boundary.
- Use the result
- Carry total input W and area; this is unadjusted W/m², with no automatic NCC limit or adjustment.
Choose the next action only when its condition applies:
The actual operating schedule is known.
Continue: Lighting Energy and Running CostAn NCC assessment or electrical loading decision is needed.
Pause: Check the applicable electrical or regulatory method
Estimate specified-period energy and optional usage costs, including distinct operating states.
Lighting Energy and Running Cost
- Before using it
- Match count, input W, non-overlapping hours and days; pair each priced state with its applicable usage rate, including standby where relevant.
- Inputs and units
- Counts, input W, non-overlapping state hours, specified days and optional usage rates; group IDs and mutually exclusive day-type counts where used.
- Result
- Energy in kWh and conditional usage cost in AUD; simple-mode A-minus-B differences or combined state/day-type totals.
- Use the result
- Keep kWh, period, group states and usage-rate basis. Fixed supply charges, demand charges and project costs are outside this usage-cost calculation.
Choose the next action only when its condition applies:
A consistent additional investment and full-year net saving are available.
Continue: Simple Lighting PaybackA constant-cost horizon, maintenance and replacement plan are needed.
Continue: Lighting Ownership CostA sourced electricity factor matches the kWh period and accounting boundary.
Continue: Lighting Operational EmissionsActual settings or product watts differ from the original comparison.
Revisit: Lighting Product ComparisonSchedules, applicable rates or comparison service are unresolved.
Pause: Resolve the comparison or budget basis
Compare additional upfront investment with a constant annual net saving.
- Before using it
- Supply a nonnegative incremental investment and a full-year net saving including relevant cost differences on a consistent service basis.
- Inputs and units
- Additional investment in AUD, annual net saving in AUD/year and a consistent comparison basis.
- Result
- Undiscounted payback in years, or an explanation when no positive payback applies.
- Use the result
- Interpret undiscounted years only under those assumptions; zero or negative saving has no positive payback.
Choose the next action only when its condition applies:
Planned replacement and maintenance costs over a chosen horizon also matter.
Continue: Lighting Ownership CostOperating hours or rates change the claimed saving.
Revisit: Lighting Energy and Running CostTwo comparable constant-cost plans and a real annual discount rate are available for a present-cost comparison.
Continue: Lighting Ownership CostA full investment appraisal or uncertain future cost forecast is required.
Pause: Resolve the comparison or budget basis
Budget one lighting option or compare the present costs of two options over whole years.
- Before using it
- Declare a constant AUD basis, horizon, annual hours, project costs and replacement plan. Comparing options also needs comparable service, a supplied real rate and acceptance of year-end cost grouping.
- Inputs and units
- Luminaire data, whole-year horizon, constant AUD costs and replacement plan; comparison adds an alternative, real annual discount rate and comparable-service declaration.
- Result
- Undiscounted budget, or both options’ present cost components and a signed baseline-minus-alternative difference on the same horizon.
- Use the result
- Keep cost components and events with each total. A positive baseline-minus-alternative present-cost difference means the alternative costs less within this model; it is not complete investment NPV or a product-life guarantee.
Choose the next action only when its condition applies:
A different operating schedule changes annual hours or energy.
Revisit: Lighting Energy and Running CostEscalation, nominal rates, exact payment dates, residual values, uncertain failures or a non-matching replacement plan must be modelled.
Pause: Resolve the comparison or budget basis
Apply a supplied electricity emissions factor to specified kWh.
Lighting Operational Emissions
- Before using it
- Record factor source, year, region, method and scopes, and match any baseline to the same period and boundary.
- Inputs and units
- Electricity kWh, supplied kg CO₂e/kWh, optional baseline kWh and the factor source, year, region, method and scopes.
- Result
- kg and tonnes CO₂e, optional baseline and signed difference; no factor or offset claim is selected.
- Use the result
- Keep kg or tonnes CO₂e and any signed baseline difference with the factor basis. The calculation chooses no factor and makes no offset claim.
Choose the next action only when its condition applies:
The operating schedule or baseline energy changes.
Revisit: Lighting Energy and Running CostA matching factor or accounting boundary is unavailable.
Pause: Obtain the missing source data
Account for an object’s light exposure
What illuminance-time exposure has this object received, and what remains within its supplied budget?
Lux-hours are an exposure account, not a damage prediction. The object-specific budget must come from an appropriate conservation basis.
Add non-overlapping object-surface illuminance/time periods and optionally calculate remaining time.
- Before using it
- Use lx at the object, hours for each period and, if needed, a budget for that object and period plus positive future lx.
- Inputs and units
- Lux and hours for each period; optional lx·h budget and positive future lx.
- Result
- Accumulated lx·h, optional remaining or excess exposure, and time at the supplied future level.
- Use the result
- Keep accumulated lx·h, remaining or excess exposure and the assumed future level. Recalculate when the level or display duration changes.
Choose the next action only when its condition applies:
New object-surface readings need conversion before updating the exposure record.
Revisit: Illuminance Unit ConverterA safe object-specific exposure budget or damage assessment is needed.
Pause: Obtain an object-specific conservation basis
Plan photographic light and exposure
Which settings and separately measured contributions describe this exposure?
Nominal exposure arithmetic needs compatible camera, source and receiver conditions. It does not predict banding, colour rendering or the output of unknown flash modifiers.
Preserve continuous-light exposure after a camera setting or ND change.
- Before using it
- Supply baseline settings and absolute baseline/target ND; hold the remaining target settings fixed. Cine time needs fps and shutter angle.
- Inputs and units
- Baseline and target camera settings, absolute ND losses or transmission stacks; optional cine fps and angle.
- Result
- Equivalent settings, ND transmission/density, setting EV and distinctly labelled unfiltered-scene equivalent EV100.
- Use the result
- Keep the solved setting with its ND and ISO basis. Setting EV differs from the unfiltered-scene equivalent EV100.
Choose the next action only when its condition applies:
A direct manual flash must supply a separately rated contribution.
Continue: Flash Guide Number CalculatorLux calibration, banding, reciprocity or real filter response must be established.
Pause: Obtain the missing source data
Solve a direct manual-flash setting from matching metric GN data.
- Before using it
- Supply full-power GN/reference ISO, shooting ISO, energy fraction, flash distance or f-number and matching zoom/attachment conditions.
- Inputs and units
- Full-power reference GN and ISO, shooting ISO, manual energy fraction, flash-to-subject distance or f-number and rating conditions.
- Result
- Nominal aperture, distance, effective GN or required energy fraction, with an explicit over-full-power result when applicable.
- Use the result
- Use the nominal aperture or distance only under the supplied rating. Multiple flashes add compatible exposure contributions, not guide numbers.
Choose the next action only when its condition applies:
Separately metered key/fill or flash/ambient contributions are available.
Continue: Lighting Ratio CalculatorBounce, TTL, HSS or unknown modifier effects replace the rated direct-flash conditions.
Pause: Obtain the missing source data
Interpret a named light ratio from comparable separate or total readings.
- Before using it
- Identify key-only/fill-only, bright/dark totals or matched flash/ambient exposure. Metered f-numbers need the same ISO and shutter.
- Inputs and units
- Two comparable linear readings or same-ISO/shutter metered f-numbers, measurement definition and conditions.
- Result
- Named light ratio, stop difference, optional declared equal-fill bright/dark model or flash exposure share.
- Use the result
- Keep the measurement definition with the ratio and stops; the additive equal-fill model is an explicit assumption.
Choose the next action only when its condition applies:
The separately metered flash contribution needs adjusting under compatible GN conditions.
Revisit: Flash Guide Number CalculatorControl-panel percentages or incompatible quantities are the only available data.
Pause: Obtain the missing source data
Describe a nominal reciprocal-CCT shift or apply a supplied shift.
- Before using it
- Supply source/target CCT in K or source CCT and a signed nominal manufacturer shift with its source conditions.
- Inputs and units
- Source and target CCT in K, or source CCT and a signed manufacturer-supplied mired shift.
- Result
- Source and target mired, signed shift and conditional target K, without a filter or tint recommendation.
- Use the result
- Interpret the mired change without assuming a particular filter achieves it on an arbitrary LED spectrum.
Choose the next action only when its condition applies:
A real filter, tint, mixed-light colour or colour-rendering choice is required.
Pause: Obtain the missing source data
Plan plant light, strip stock and measured signals
Do I need a daily photon plan, continuous strip pieces, or a description of measured optical data?
These tasks have separate inputs and conditions. Spectral data cannot replace missing installation, biological or electrical requirements.
Plan an incremental supplement against a supplied DLI target and window.
- Before using it
- Provide baseline DLI or representative PPFD/time periods, sourced target, incremental supplement PPFD and available hours. Exclude the planned supplement from baseline.
- Inputs and units
- Baseline DLI or representative PPFD/time periods, sourced target DLI, incremental supplement PPFD and available hours per day.
- Result
- Baseline, numerical dose gap, required and planned hours, achievable total and remaining gap.
- Use the result
- Keep the required time, achievable dose and remaining gap with the daily window; do not infer a crop target or extend the photoperiod.
Choose the next action only when its condition applies:
Whole-system input W and the planned operating hours are known.
Continue: Lighting Energy and Running CostThe plant-specific target or representative PPFD measurements are unknown.
Pause: Obtain the missing source data
Allocate varied continuous strip runs to usable stock and new reels.
- Before using it
- Supply matching usable lengths, cut interval, permitted origins, run lengths/counts and a floor or ceiling rule. No splice or cutting loss is assumed.
- Inputs and units
- Run targets and counts, existing usable pieces, new reel length, manufacturer cut interval and floor or ceiling rule.
- Result
- Per-run cut lengths, per-stock allocations, new reel count, remaining stock, unmet runs and an explicit optimisation status.
- Use the result
- Review each allocation and unmet run. A feasible arrangement is labelled minimum only when the bounded method proves it.
Choose the next action only when its condition applies:
One repeated target needs examining against cut intervals or per-metre ratings.
Revisit: LED Strip Cut-length PlannerPower supply, wiring or maximum connected run suitability must be decided.
Pause: Check the applicable electrical or regulatory method
Describe a complete-cycle linear optical waveform.
- Before using it
- Supply nonnegative equal-duration samples or constant levels with positive durations, and instrument/cycle conditions.
- Inputs and units
- Nonnegative equal-duration optical samples, or constant levels with positive durations, and their measurement conditions.
- Result
- Sampled extrema, time-weighted mean, percent modulation and flicker index; no health or camera-banding rating.
- Use the result
- Keep percent modulation and flicker index with the supplied sampling basis; neither is a health or camera-banding verdict.
Choose the next action only when its condition applies:
PstLM, SVM, safe exposure or camera shutter compatibility is required.
Pause: Review the measurement basis before deciding
Integrate spectra, convert existing chromaticity coordinates, or explore monochromatic optical photons.
- Before using it
- For spectra, identify scale, wavelength coverage and representation; mixing needs matching calibration/geometry. For existing coordinates, identify xy, 1960 uv or 1976 u′v′ and retain the source observer.
- Inputs and units
- Spectral nodes or bands with their scale and coverage; existing chromaticity coordinates and observer basis; or monochromatic wavelength, photon energy or optical rate.
- Result
- Spectral and photopic integrals, conditional photon quantities and xy/1960 uv/1976 u′v′; or monochromatic photon energy and rates. No CCT or colour-rendering judgement.
- Use the result
- Retain the scale and coverage with photon quantities, or the observer with converted coordinates. Relative data cannot yield absolute PPF without calibration; coordinate conversion does not change the observer.
Choose the next action only when its condition applies:
Absolute receiving-plane PPFD and representative daily periods have been established.
Continue: Daily Light Integral PlannerMatching whole-luminaire PPF and system W are ready for group comparison.
Continue: Lighting Schedule TotalsThe spectral scale, coverage or colour-rendering method is missing.
Pause: Obtain the missing source data
When the calculation is not the next step
Obtain the missing source data
Request the exact product, instrument, factor or method data named in the branch. Keep its units, setting, date and conditions; do not substitute an unrelated default.
Use project-specific lighting design
Bring actual photometry, room and surface information, task plane, layout and project requirements to a suitable lighting professional. These arithmetic tools do not assess glare, full distributions or compliance.
Check the applicable electrical or regulatory method
For electrical selection use a licensed electrical professional with the actual load and installation data. For an NCC assessment establish the jurisdiction, edition, building scope and applicable method; unadjusted watts alone are insufficient.
Review the measurement basis before deciding
Check instrument range and calibration, representative locations, plane, time, daylight and operating conditions. Resolve differences against the relevant measurement method and project requirements before changing a design factor or declaring a pass.
Resolve the comparison or budget basis
Collect a consistent full-year schedule, applicable tariff and relevant project costs; check comparable lighting service separately. Use a suitable financial method if discounting, escalation or uncertainty is material.
Obtain an object-specific conservation basis
Ask a suitable conservator for the object’s sensitivity, budget period and display conditions. Do not infer a safe limit from the lux-hour arithmetic.
Links open separate tools without transferring or storing entries. Keep the original values, units and conditions. A feedback link means reviewing the original basis, not changing a factor solely to match a desired result.
Related task examples
These groups collect related calculations for reference. They are optional branches, not a required sequence; use the decision tree above to check each calculation’s conditions.
Prepare and explore a lighting plan
How do product data, room dimensions, a maintained average and a coordinate sketch fit together?
Lighting Product Comparison
Keep the exact model, setting, initial luminaire lm and input W together.
Room Index and Working-plane Geometry
Record area, source-to-plane height and K. Consult only a matching utilisation method; K does not select UF.
Maintenance Factor Composition
Keep the unrounded MF and the common maintenance basis. Do not apply an included loss twice.
Lumen Method Estimate
Use the declared initial output, area, UF/MF and supplied target. The rounded count is an arithmetic proposal.
Rectangular Lighting Grid Geometry
Try rows and columns for a geometric sketch; a changed layout may require checking the original utilisation assumptions.
Lighting Schedule Totals
Record the actual groups and total input power for the operating-cost task.
An average and a grid do not establish point illuminance, glare, uniformity or installation compliance. Actual photometry and project requirements remain necessary.
Check and interpret illuminance readings
What do the recorded readings represent, and how do they compare with a conditional model?
Illuminance Unit Converter
Convert the same measured quantity to lx without changing its measurement conditions.
Illuminance Meter Specification Range
Keep the actual additive meter specification and its conditions with the reading. A tolerance band is not a confidence interval.
Illuminance Sample Statistics
Retain the individual readings and representative-area basis. A mean does not establish every location’s light level.
Paired Daylight Factor
For the daylight branch only, pair simultaneous indoor and unobstructed outdoor readings under the stated sky conditions. Do not use a mixed artificial-light reading.
Point-source Illuminance
Compare only a compatible direct contribution using directional cd, ray distance and incidence angle; reflected and other light are additional.
A sample statistic cannot validate a measurement grid, meter calibration or standards compliance. Keep the plane, time, daylight and operating conditions with the readings.
Budget and compare lighting operation
How much power and energy does the declared schedule use, and what does a supplied saving imply for payback?
Measured Dimming Curve Interpolation
When estimating a measured dimming setting, carry its paired lm and input W with the same driver/control conditions; otherwise use the actual product data.
Lighting Schedule Totals
Carry each group’s count and matching input watts. Keep separate schedules when operating hours differ.
Lighting Power Density
Use the same whole-luminaire input boundary and matching floor area. Unadjusted W/m² is not an NCC verdict.
Lighting Energy and Running Cost
Add operating time and the applicable usage rate. For payback, supply a full-year net saving that also accounts for relevant cost differences.
Simple Lighting Payback
Keep the additional investment and constant full-year net saving with the result. Zero or negative saving has no positive payback.
Lighting Ownership Cost
For a whole-horizon budget, add project upfront costs, annual maintenance and an explicit planned replacement interval without counting the same costs twice.
Lighting Operational Emissions
For the emissions branch, carry kWh and its period into a separately sourced matching kg CO₂e/kWh factor; costs do not supply this factor.
Lower electricity use does not establish equivalent lighting service. Match the comparison period, tariff and cost basis, and check the service independently.
Separate beam geometry from light quantities
Which calculation describes an outline, an ideal flux distribution or direct illuminance at one point?
Beam Spread Geometry
Carry a compatible circle diameter only for the perpendicular, symmetric geometry being modelled.
Circular Beam Overlap Geometry
Interpret shared geometric area separately from illuminance and uniformity.
Uniform Cone Luminous Flux
Use constant intensity throughout an ideal cone; a real peak-candela rating is insufficient.
Point-source Illuminance
Use the intensity towards the particular point and the actual ray distance and incidence angle.
Diffuse Surface Luminance
For an ideal non-emitting Lambertian reflector, use incident surface lx and matching diffuse luminous reflectance. A glossy surface needs another model.
Uniform Disc On-axis Illuminance
Use uniform luminance only when the actual disc and parallel on-axis geometry fit. The preceding reflected-surface result is not automatically suitable disc data.
Do not turn a beam angle and peak candela into real total lumens or room lux. Each model requires its own declared distribution and geometry.
Account for an object’s light exposure
How much illuminance-time exposure has one object received, and what remains within a supplied budget?
Illuminance Unit Converter
Use readings on the object surface and convert to lx where needed.
Light Exposure Budget
Keep non-overlapping time periods, the object-specific budget and the assumed future illuminance together.
An exposure budget must suit the object and period. Lux-hours do not predict damage, and the calculator chooses no conservation limit.
An artificial project across the tools
This example connects the arithmetic; its product data, factors, target and prices are invented assumptions. It is not a recommended lighting design. Comparable lighting service is assumed to have been checked separately.
| Task and inputs | Independently calculated result | What to keep |
|---|---|---|
| 10 × 5 m rectangle; source 3 m and plane 1 m above one datum | 50 m²; h = 2 m; K = 5/3 | The actual geometry and reference plane |
| LLMF .9, LSF 1, LMF .8, RSMF .95 | MF = .684 | The common maintenance plan; these are artificial factors |
| 3,000 initial lm per luminaire, UF .6, MF .684, supplied target 350 lx | ceil(17,500/1,231.2) = 15 luminaires; modelled average 369.36 lx | Initial output and explicit factor basis; 350 lx is not a recommendation |
| 3 rows × 5 columns in that rectangle | 15 grid points; x spacing 2 m, y spacing 5/3 m | A geometric sketch, subject to a new distribution check |
| 15 luminaires, 3,000 initial lm and 20 W each | 45,000 lm, 300 W; 6 W/m² over 50 m² | Whole-luminaire input, including required drivers |
| 15 × 20 W × 5 h/day × 300 operating days/year at AUD.30/kWh | 450 kWh/year; AUD135/year in usage cost | The remaining days have zero use in this artificial schedule; no standby cost is assumed |
| Baseline: 20 × 25 W, same hours/days and rate; additional investment AUD360 | Baseline 750 kWh and AUD225/year; net annual saving AUD90; simple payback 4 years | Comparable service and no other net annual cost differences are explicit assumptions |
After a change, readings such as an artificial 340, 360 and 380 lx have a sample mean of 360 lx. That does not prove a 350 lx target is met at every location or identify why the model and readings differ. Check measurement conditions and representativeness before changing the design assumptions.
Keep the basis with the number
These are linked tasks, not an automated design or product-selection service. Entries remain in each calculator; opening another tool does not transfer or store them. Carry the unrounded source values, units and conditions yourself, then check that the next model accepts that basis.
After installation or a change in operating conditions, compare new measurements with the original assumptions. A difference can reflect distribution, daylight, maintenance, instrument limitations or a different measurement plane; changing a coefficient solely to match the reading does not explain the cause.
Browse every calculator or read how inputs and results are handled.