Light Exposure Budget

Add lux-hours across exposure periods and compare them with your own budget, with optional remaining-time arithmetic.

Accumulate lux-hours from constant or representative-average illuminance during each period. Supply your own object-specific budget if you want remaining-time arithmetic.

Results update as you edit.

Calculating needs JavaScript. The form becomes available when its script is ready; the guide below is always readable.

Calculation inputs

Calculation inputs
One period per line, for example 50, 8. Use 1–100 rows with finite nonnegative values. Periods must not double-count the same exposure.
Zero or more, covering the same object and accounting period. Blank leaves the budget comparison unavailable.
Greater than zero. With a budget, remaining hours = remaining lx·h divided by this level. Leave blank if no future-time estimate is needed.

Continue your task

Keep accumulated lx·h, remaining or excess exposure and the assumed future level. Recalculate when the level or display duration changes.

If this answers your question within the model’s limits, record the original inputs, unrounded result and conditions. Otherwise choose an action only when its condition applies:

See this task in the decision tree

Opening another tool does not transfer or store your entries. Keep the original values, units and conditions with the next calculation.

Illuminance and duration describe different parts of exposure

A lux reading describes illumination at a surface at a particular time. An object left under that light accumulates exposure for as long as the condition continues. The Canadian Conservation Institute’s explanation of light and its exposure defines the practical quantity as illuminance multiplied by duration, expressed in lux-hours.

For one constant period, exposure = illuminance in lx × time in hours. For several periods, add their products:

Total exposure = Σ(E × t), in lx·h.

This is different from the electrical energy consumed by the lights. A lamp’s watts do not tell you the lux received by an object, and kWh cannot be substituted for lx·h. The energy tool answers the separate electricity question.

Combine changing periods without double-counting

Suppose an artificial display receives 50 lx for 8 hours, then 150 lx for another 2 hours. Its exposure is:

Period Illuminance Duration Exposure
First 50 lx 8 h 400 lx·h
Second 150 lx 2 h 300 lx·h
Total — 10 h 700 lx·h

These periods occur in sequence. Do not enter an overall period and also its component periods, because that would count the same exposure twice. If the illuminance changes continuously, a representative time average or a finer set of periods is needed. A short peak reading applied to every hour may overstate exposure; a single low reading can understate it.

Zero lux or zero duration contributes zero exposure. An empty value is missing information, not a zero reading. The displayed exposure rounds to two decimal places while the calculation retains its intermediate values.

Translate a supplied budget into time

Assume an artificial budget of 1,000 lx·h for the same object and accounting period. After the 700 lx·h above, 300 lx·h remains. At a future constant 50 lx, that permits 300/50 = 6.00 hours within this arithmetic budget.

If the budget were 600 lx·h, the accumulated exposure would exceed it by 100 lx·h. Remaining time would be zero, not a negative allowance. A blank budget leaves this comparison unavailable while retaining the calculated exposure. The calculator supplies no recommended budget.

A dose alone does not predict damage

Two lighting conditions with equal lux-hours need not have the same effect on every material. Spectral distribution, object sensitivity, UV, IR, previous exposure and other conditions matter. This tool does not estimate fading, material lifetime or a safe display policy.

Use a reading for the relevant object surface. If its unit is foot-candles or kilolux, convert the same illuminance before using it. Several spatial readings from different objects are not automatically a time series for one object, even if their sample statistics are available.

Related tools

Lighting Energy and Running Cost

Estimate lighting kWh and usage cost with simple comparisons, mixed operating states, or different day types and seasonal schedules.

Inputs and results
Inputs
Counts, input W, non-overlapping state hours, specified days and optional usage rates; group IDs and mutually exclusive day-type counts where used.
Results
Energy in kWh and conditional usage cost in AUD; simple-mode A-minus-B differences or combined state/day-type totals.

Illuminance Unit Converter

Convert the same illuminance between lux, kilolux and foot-candles, with metric units shown first.

Inputs and results
Inputs
A nonnegative illuminance and its unit: lx, klx or fc.
Results
The same illuminance in lx, klx and fc.

Illuminance Sample Statistics

Summarise spatial lux or PPFD samples with a supplied reference, or describe daylight occupied-time coverage with missing periods kept explicit.

Inputs and results
Inputs
Same-basis spatial lux/PPFD and represented areas, or daylight-only zone/time records, occupied horizon and user threshold.
Results
Spatial descriptive statistics and reference shares, or daylight area-time coverage bounds, observed mean and recorded exposure.

Browse all lighting tools