Lighting Power Density

Calculate unadjusted whole-luminaire input power per floor area from groups of lights. No NCC compliance verdict.

Add whole-luminaire input power for groups of lights and divide by the matching floor area. This is unadjusted arithmetic, without an NCC allowance or compliance verdict.

Results update as you edit.

Calculating needs JavaScript. The form becomes available when its script is ready; the guide below is always readable.

Calculation inputs

Calculation inputs
Use a finite area greater than zero for the same boundary as all the included lights.
One group per line, for example 12, 18 means twelve luminaires at 18 W each. Use positive whole counts and whole-luminaire input watts including required drivers. No blank internal rows or thousands separators.
Keep operating settings consistent. Do not substitute LED-chip watts, output watts or a nominal replacement wattage.

Continue your task

Carry total input W and area; this is unadjusted W/m², with no automatic NCC limit or adjustment.

If this answers your question within the model’s limits, record the original inputs, unrounded result and conditions. Otherwise choose an action only when its condition applies:

See this task in the decision tree

Opening another tool does not transfer or store your entries. Keep the original values, units and conditions with the next calculation.

Input watts spread across a defined floor area

Unadjusted lighting power density divides the total electrical input of the included luminaires by the matching floor area: W/m² = Σ(count × input W each) ÷ area in m². It is an electrical-input measure. It does not say how much light reaches a desk, how evenly the room is lit or whether a fitting’s colour and glare characteristics suit the task.

Keep the power and area boundaries together. If the area is one room, include the luminaires serving that boundary on a consistent operating basis. Adding another room’s lights without adding its area inflates the result; adding unserved floor area reduces it without changing the lights.

Use whole-luminaire input, including the driver

YourHome’s lighting guidance distinguishes electrical power from light output and discusses integrated LED luminaires. For this arithmetic, use electrical input for the whole luminaire at the stated setting, including a required driver. LED-chip watts, nominal replacement watts and lumens are different figures.

Group lights only when their input watts match. Different fittings or settings need separate groups. For an artificial example, twelve luminaires at 18 W each total 216.00 W. Dividing by 36 m² gives 6.00 W/m².

Mixed groups can have the same total

Ten luminaires at 12 W plus two at 48 W also total 10 × 12 + 2 × 48 = 216 W. Over the same 36 m², the result remains 6.00 W/m². The identical density does not establish equivalent light output, distribution or operating cost.

The total uses unrounded inputs. Watts and W/m² display to two decimal places, with very small positive results identified rather than rounded to zero. Counts must be positive whole numbers and floor area must be greater than zero.

Why this is not an NCC assessment

A raw W/m² value is only one arithmetic quantity. An applicable NCC assessment can depend on building classification, adopted edition, jurisdiction, space definition and the relevant method’s allowances or adjustments. This tool applies none of those rules and has no maximum-value table or pass/fail output. Comparing its number to an unrelated limit would not establish compliance.

Operating time is a separate question. To turn a declared input power and operating schedule into energy, use the lighting energy and running cost calculator. A lower W/m² value alone cannot establish lower annual energy if operating hours change.

Related tools

Lighting Product Comparison

Compare two products and calculate luminaire efficacy, or convert lumens and input watts using a supplied matching efficacy.

Inputs and results
Inputs
Product specifications; conversion requires a supplied luminaire lm/W value, known lm or W and matching-data conditions.
Results
A side-by-side record and conditional lm/W; a separate conversion calculates lm or W under your supplied efficacy.

Lighting Energy and Running Cost

Estimate lighting kWh and usage cost with simple comparisons, mixed operating states, or different day types and seasonal schedules.

Inputs and results
Inputs
Counts, input W, non-overlapping state hours, specified days and optional usage rates; group IDs and mutually exclusive day-type counts where used.
Results
Energy in kWh and conditional usage cost in AUD; simple-mode A-minus-B differences or combined state/day-type totals.

Browse all lighting tools