Daily Light Integral Planner

Calculate baseline DLI and the supplemental light time needed for your supplied target within a limited daily window.

Plan incremental supplemental light against your own daily light integral (DLI) target and a limited daily window. Use a measured baseline DLI or nonoverlapping representative PPFD/time periods.

Results update as you edit.

Calculating needs JavaScript. The form becomes available when its script is ready; the guide below is always readable.

Calculation inputs

Calculation inputs
Zero or more, excluding the additional supplement being planned. Leave blank when entering PPFD/time rows below.
Optional alternative to baseline DLI: up to 100 nonoverlapping rows of representative mean PPFD in µmol·m⁻²·s⁻¹, hours. Total no more than 24 h/day. Missing periods must not silently become zero.
Zero or more. Record the source and the plant, growth stage and conditions in the basis field.
Zero or more at the same receiving position. Use the added PPFD from the supplement alone, not an already combined daylight-plus-lamp reading.
0–24 h/day. The plan never extends this supplied window automatically.
Identify target source or assumption, receiving position, plant/stage, representative periods, baseline coverage and supplement measurement conditions.
This prevents adding the same lamp contribution twice. The supplement can operate during daylight if its PPFD is a measured increment.

Continue your task

Keep the required time, achievable dose and remaining gap with the daily window; do not infer a crop target or extend the photoperiod.

If this answers your question within the model’s limits, record the original inputs, unrounded result and conditions. Otherwise choose an action only when its condition applies:

See this task in the decision tree

Opening another tool does not transfer or store your entries. Keep the original values, units and conditions with the next calculation.

A daily amount needs more than one light reading

Daily light integral, or DLI, is the quantity of photosynthetically active photons arriving at a surface over a day, expressed in mol·m⁻²·day⁻¹. PPFD is their arrival rate in µmol·m⁻²·s⁻¹. Purdue’s DLI guidance explains why both light intensity and duration matter: the same midday reading can belong to days with very different morning, afternoon and cloud conditions.

For a period with a representative mean PPFD P lasting h hours, its contribution is DLI = P × h × 0.0036. The factor converts hours to seconds and micromoles to moles: 3,600/1,000,000 = 0.0036. Add the contributions from nonoverlapping periods to obtain the entered baseline. A hypothetical 300 µmol·m⁻²·s⁻¹ maintained for 12 hours contributes 12.96 mol·m⁻²·day⁻¹.

A representative mean may come from suitably sampled measurements over the stated period. An isolated instantaneous reading is not automatically that mean. A missing period is also not a measurement of zero light. Keep the measurement position, dates, sampling coverage and any genuinely zero-light periods with the baseline. Results apply to that receiving position; an average daily dose at one point does not describe every plant in an unevenly lit area.

Close the gap with additional photons

The plan compares a supplied target with the existing baseline:

Gap = max(target DLI − baseline DLI, 0)

At a constant incremental supplement PPFD S, required supplement hours = gap/(S × 0.0036). “Incremental” means the additional light from the supplement at the same receiving position. If the baseline already includes those photons, adding them again overstates the planned total. A supplement can operate while daylight is present, provided its entered PPFD is the added contribution and the baseline excludes that additional contribution.

An artificial target of 18 and a baseline of 7.2 leave a gap of 10.8 mol·m⁻²·day⁻¹. At an incremental 250 µmol·m⁻²·s⁻¹, each hour adds 0.9 mol·m⁻², so closing the gap requires 12 hours. These invented values illustrate arithmetic; the target is not a recommendation for a crop or growth stage.

Available supplement window Time used by this plan Additional DLI Planned total DLI Remaining gap
10 h/day 10 h/day 9.00 16.20 1.80
12 h/day 12 h/day 10.80 18.00 0.00
14 h/day 12 h/day 10.80 18.00 0.00

DLI values in the table are mol·m⁻²·day⁻¹. The plan uses only enough of an adequate window to close the numerical gap. An insufficient window remains insufficient; it is not automatically extended. With zero incremental PPFD, a positive gap cannot be closed. If the baseline already meets the target, the required additional time is zero.

Keep the target and time window separate

The target determines the numerical daily gap. The allowable window is a separate input: a daily amount alone does not establish a suitable photoperiod, peak PPFD or lighting schedule. Keep the target’s source and its plant, growth-stage and environmental conditions alongside the result. The calculation does not infer those conditions from a plant name or choose a target for Australian growing conditions.

Displayed hours are rounded to two decimal places, while the feasibility check retains the entered decimal quantities. For example, a gap of 12 at 250 µmol·m⁻²·s⁻¹ requires 13⅓ hours. A window of 13.33 hours is slightly shorter even though the required time also displays as 13.33. A small remaining gap is still a gap; a rounded display is not a reason to treat it as zero.

Use photon measurements on a matching basis

Lux weights light for human photopic vision; PPFD counts photons in the stated photosynthetic band. Apogee’s conversion discussion shows that their relationship depends on the spectrum. A universal lux-to-PPFD factor would conceal that dependence. Use an appropriate quantum measurement or matching spectral information, retaining the sensor’s spectral response, calibration and position.

The operating time can then support an electricity and running-cost estimate, using the complete lighting system’s actual input watts. PPFD is a receiving-plane quantity; multiplying it by hours does not reveal the luminaire’s electricity use or the driver’s losses.

Related tools

Lighting Energy and Running Cost

Estimate lighting kWh and usage cost with simple comparisons, mixed operating states, or different day types and seasonal schedules.

Inputs and results
Inputs
Counts, input W, non-overlapping state hours, specified days and optional usage rates; group IDs and mutually exclusive day-type counts where used.
Results
Energy in kWh and conditional usage cost in AUD; simple-mode A-minus-B differences or combined state/day-type totals.

Illuminance Sample Statistics

Summarise spatial lux or PPFD samples with a supplied reference, or describe daylight occupied-time coverage with missing periods kept explicit.

Inputs and results
Inputs
Same-basis spatial lux/PPFD and represented areas, or daylight-only zone/time records, occupied horizon and user threshold.
Results
Spatial descriptive statistics and reference shares, or daylight area-time coverage bounds, observed mean and recorded exposure.

Lighting Spectrum Workbench

Integrate and mix spectra, calculate conditional PPF, PPFD, PPE and chromaticity, convert CIE xy/uv/u′v′ coordinates, or explore monochromatic photon energy.

Inputs and results
Inputs
Spectral nodes or bands with their scale and coverage; existing chromaticity coordinates and observer basis; or monochromatic wavelength, photon energy or optical rate.
Results
Spectral and photopic integrals, conditional photon quantities and xy/1960 uv/1976 u′v′; or monochromatic photon energy and rates. No CCT or colour-rendering judgement.

Browse all lighting tools