Lighting Spectrum Workbench

Integrate and mix spectra, calculate conditional PPF, PPFD, PPE and chromaticity, convert CIE xy/uv/u′v′ coordinates, or explore monochromatic photon energy.

Integrate supplied spectral data, mix two matching channels, convert existing chromaticity coordinates, or explore a monochromatic optical model. Absolute flux, irradiance and relative data have different result units. The example is an invented rectangular spectrum.

Results update as you edit.

Calculating needs JavaScript. The form becomes available when its script is ready; the guide below is always readable.

Calculation inputs

Calculation inputs
Use spectral data for a broad spectrum, or convert coordinates already supplied by a report or instrument. A monochromatic model assigns every photon the same wavelength.
Check the report: 1960 v and 1976 v′ are different. Changing this selector reinterprets the numbers below; it does not convert the input fields.
Nonnegative ordinary decimal, up to 80 characters. Use the first coordinate from the selected system.
Nonnegative ordinary decimal, up to 80 characters. A prime mark matters: v′ = 1.5 × v.
Record the report or instrument, standard observer (such as 2° or 10°), operating state and measurement conditions. Conversion preserves this basis; it does not change the observer.
Use a single matching quantity for both channels. Electrical input watts are not spectral radiant flux.
Nodes are linearly interpolated. Bands are constant within adjacent start/end intervals; known zero gaps need explicit zero bands.
Bands: start nm, end nm, density A. Nodes: wavelength nm, density A. When mixing, append density B in the same units and grid. Positive wavelengths ≤1,000,000 nm; nonnegative densities; up to 2,000 rows, without a header.
Append channel B to every row, then apply the weights before integration.
Used only when mixing. Zero or more; a multiplier is not automatically a dimmer setting or electrical-power fraction.
Used only when mixing. For relative data, the matching calibration basis determines what this contribution means.
An entire luminaire spectrum cannot be added to a point irradiance spectrum.
Select only for a justified zero-output boundary. An instrument that did not measure those wavelengths does not justify this declaration.
Divides every combined density by its entered-range spectral integral. The resulting nm⁻¹ curve describes relative shape, without absolute calibration; an all-zero curve cannot be normalised.
Record the source, density units, calibration, operating state, receiving geometry and any unmeasured wavelength ranges.
Positive, used only with absolute flux and complete 400–700 nm coverage to calculate PPE. Enter power for the combined operating state; it is not inferred from channel weights.
Single-photon energy and wavelength describe each photon. Optical radiant power and photon flux additionally require a rate.
Vacuum wavelength, positive and no more than 1,000,000 nm. Only 400–700 nm photons belong to the conventional PPF band.
Positive decimal; enter 3 for 3 × 10⁻¹⁹ J per photon. The resulting wavelength must be no greater than 1,000,000 nm. This is energy for one photon, not W or electrical energy.
Zero or more in the input unit selected above. Use radiant optical watts, not electrical input watts.
A broad-spectrum LED or lamp does not have one interchangeable photon-energy wavelength.

Continue your task

Retain the scale and coverage with photon quantities, or the observer with converted coordinates. Relative data cannot yield absolute PPF without calibration; coordinate conversion does not change the observer.

If this answers your question within the model’s limits, record the original inputs, unrounded result and conditions. Otherwise choose an action only when its condition applies:

See this task in the decision tree

Opening another tool does not transfer or store your entries. Keep the original values, units and conditions with the next calculation.

Start with the quantity represented by the spectrum

A spectrum assigns an optical quantity to each wavelength. Its vertical scale determines what can be calculated. A total luminaire spectrum in W/nm integrates to radiant watts. A receiving-plane spectrum in W·m⁻²·nm⁻¹ integrates to irradiance in W/m². Their photon-weighted results are PPF and PPFD respectively; an entire luminaire’s output does not specify the amount reaching one point.

An uncalibrated relative curve preserves spectral shape but has no absolute optical scale. It can produce relative integrals and CIE chromaticity coordinates. It cannot supply absolute lumens, lux, PPF, PPFD or photon efficacy merely because its peak is labelled 1 or 100. If data has been calibrated externally, enter the resulting absolute density with its units and calibration basis.

Unit-area normalisation divides every density by the integrated area over the entered range. The resulting relative density has units nm⁻¹ and integrates to 1 under the same representation. For the artificial 1 W/nm band on 659–661 nm, its 2 W integral gives a normalised density of 0.5 nm⁻¹ across that band. This changes the representation of the shape, not the original absolute results; a zero-area spectrum cannot be normalised.

Make the wavelength representation and coverage explicit

Two supported representations describe different functions:

  • Linear nodes: each row gives wavelength and density. Density varies linearly between adjacent nodes, and wavelengths must increase strictly.
  • Constant bands: each row gives a start wavelength, end wavelength and density that remains constant over that band. Bands must be adjacent and ordered. A known zero gap is an explicit zero-density band, rather than an omitted interval.

These choices matter near sharp edges. A band from 659 to 661 nm at 1 W/nm is a rectangle with area 2 W. Linear nodes at 659 nm and 661 nm, both at 1 W/nm, also describe a constant value between those nodes. Adding zero nodes outside them instead creates linear ramps and changes the integrated area. Neither representation can recover narrow features that were not measured.

The 400–700 nm photon result requires that whole band to be covered, or a justified declaration that output is zero outside the entered range. CIE xy and the photopic integral use the observer’s 360–830 nm range and require the corresponding coverage. An instrument that measured only part of a band has left the remainder unknown. It has not established zero output there. The integrated area over the entered range remains useful and is labelled on that basis.

Photon integration weights radiant energy by wavelength

For monochromatic light, each photon has energy E = hc/λ. Longer-wavelength photons carry less energy, so the same radiant wattage produces more photons at a longer wavelength. Using wavelength in nm and spectral radiant density Pλ in W/nm:

PPF = [10⁻³/(hcNₐ)] × ∫₄₀₀⁷⁰⁰ λPλ dλ

The factor converts nm to metres and mol to µmol. The calculation uses the exact NIST constants: h = 6.62607015 × 10⁻³⁴ J·s, c = 299,792,458 m/s and Nₐ = 6.02214076 × 10²³ mol⁻¹. The DLC horticultural requirements describe the conventional 400–700 nm PPF band and PPE in µmol/J; their North American qualification thresholds are not used here.

For an artificial exact rectangular spectrum of 1 W/nm from 659 to 661 nm, with known zero output elsewhere, the radiant integral is 2 W. The wavelength-weighted integral is (661² − 659²)/2 = 1,320 W·nm. Its PPF is 11.0343383424 µmol/s, displayed as 11.0343 µmol/s. The wavelength integral is taken before display rounding.

With irradiance-density inputs, the same operation gives PPFD in µmol·m⁻²·s⁻¹, on the stated receiving geometry. With total-flux inputs and independently supplied matching whole-system input power, PPE = PPF/input W. Electrical watts are a separate input; radiant watts do not establish the system’s electricity use.

A single-wavelength model has a narrower meaning

The monochromatic mode applies photon flux = radiant W × λnm × 10⁻³/(hcNₐ), or its inverse. At 660 nm, 2 radiant W gives the same 11.0343 µmol/s as the symmetric artificial rectangle above. A monochromatic wavelength outside 400–700 nm still has a photon flux, but it is outside conventional PPF. A broad white LED cannot be represented by one wavelength chosen from its colour temperature.

The same relationship gives energy per photon = hc × 10⁹/λnm, in joules, using vacuum wavelength. Its inverse is λnm = hc × 10⁹/energy per photon. At 660 nm, one photon carries approximately 3.00976645 × 10⁻¹⁹ J. An independently specified energy of 3 × 10⁻¹⁹ J per photon corresponds to approximately 662.1486 nm. The energy input uses multiples of 10⁻¹⁹ J, so the latter example is entered as 3; results identify the full joule value.

Energy per photon is distinct from radiant power. Knowing a photon’s energy establishes its wavelength, but total radiant watts also require a photon arrival or emission rate. A result for one photon therefore does not infer a lamp’s output, receiving-plane illumination or electrical consumption.

Mix matching spectra before calculating their metrics

For two channels, the combined density is Pmix(λ) = aPₐ(λ) + bPᵦ(λ). Both channels must use the same wavelength representation, density units, calibration basis and measurement geometry. The calculation applies these multipliers to every wavelength before integrating.

A multiplier represents a declared optical contribution. It does not predict how an LED’s spectrum, input watts or temperature changes with an electrical control setting. For relative curves, independently normalising both peaks to 1 can remove the relative scale needed for a meaningful physical mixture. Establish that scale before assigning channel weights.

CIE xy describes chromaticity rather than colour rendering

The workbench integrates the declared spectrum against the CIE 1931 2° colour-matching functions to form proportional X, Y and Z values. It then calculates x = X/(X + Y + Z) and y = Y/(X + Y + Z). Multiplying the entire spectrum by one positive factor changes X, Y and Z together, leaving xy unchanged. An integrated zero signal has no defined chromaticity.

The data is from the CIE 1931 standard colorimetric observer dataset, DOI 10.25039/CIE.DS.xvudnb9b, published by the International Commission on Illumination in 2019. Its 1 nm table covers 360–830 nm. The dataset is adapted to TypeScript with unchanged numerical values under CC BY-SA 4.0; the source format has changed. Colour-matching functions are linearly interpolated. Integration splits at their 1 nm knots and integrates the product with the chosen spectral representation; this numerical rule does not remove measurement or interpolation uncertainty.

For an independently reproducible artificial 1 W/nm band from 555 to 556 nm, known zero elsewhere, averaging the two CIE endpoint rows gives proportional X = 0.520173, Y = 0.99992835, Z = 0.0055267995. Thus x = 0.3410 and y = 0.6554 after rounding to four decimal places. The full-precision values remain in the calculation.

The photopic result weights the same absolute spectrum by y-bar and 683 lm/W, following the CIE luminous-flux relationship. Total spectral radiant flux produces lumens; spectral irradiance produces lux. These weighted integrals depend on spectral shape, so there is no universal lux-to-PPFD factor. Chromaticity also does not establish CRI, TM-30, CCT, Duv, a crop response or a health outcome.

Convert existing xy, uv or u′v′ coordinates

A product report or colour meter may already supply chromaticity coordinates. Those two numbers and their coordinate system are sufficient for conversion; a spectrum is not required. Keep the source, standard observer, operating state and measurement conditions with them. Prime marks matter: CIE 1960 v and CIE 1976 v′ are different quantities. Assigning the same numbers to another coordinate system changes the point they describe, so the input-system selector reinterprets entries rather than replacing them with converted values.

The CIE 1976 UCS definition, from CIE S 017:2020, gives the transformations below. With D = −2x + 12y + 3:

  • u = u′ = 4x/D
  • v = 6y/D
  • v′ = 9y/D = 1.5v

The inverse transformations follow algebraically. For CIE 1960 uv, set q = 2u − 8v + 4, then x = 3u/q and y = 2v/q. For CIE 1976 u′v′, set q = 6u′ − 16v′ + 12, then x = 9u′/q and y = 4v′/q. All three result pairs describe the same supplied chromaticity. Results from spectral mode also include both UCS pairs, calculated from the unrounded xy values.

For the artificial input x = 0.3127, y = 0.3290, D = 6.3226. Thus u = 1.2508/6.3226 = 0.197830, v = 1.974/6.3226 = 0.312213, and v′ = 2.961/6.3226 = 0.468320, to six decimal places. These are given coordinates for checking arithmetic, rather than a claim about a particular lamp. As a reverse example, u = 0.2, v = 0.3 gives q = 2 and x = y = 0.3, with u′ = 0.2, v′ = 0.45.

Conversion retains the standard observer of the supplied coordinates. A result derived from 10° data remains on that basis; the transformation cannot turn it into a 2° measurement. The spectrum calculation above uses the CIE 1931 2° observer because it integrates that specific dataset. Retain the observer and measurement conditions when comparing reports.

For nonnegative normalised XYZ, the coordinates must satisfy x + y ≤ 1, u + 10v ≤ 4, or 3u′ + 20v′ ≤ 12, as applicable. The tool checks these boundaries using the entered decimals before rounding. These are mathematical constraints, not a check against the visible spectral locus. Passing them does not establish that a real light source can produce the entered point. In particular, the mathematical xy origin represents the Z axis, while a zero optical signal has undefined chromaticity.

Coordinates alone do not recover a unique spectrum or establish brightness, colour rendering or a product match. The tool does not calculate a distance between two colours, a MacAdam-step count, or signed Duv from a black-body locus. Keep those tasks distinct when reading a specification.

Related tools

Lighting Product Comparison

Compare two products and calculate luminaire efficacy, or convert lumens and input watts using a supplied matching efficacy.

Inputs and results
Inputs
Product specifications; conversion requires a supplied luminaire lm/W value, known lm or W and matching-data conditions.
Results
A side-by-side record and conditional lm/W; a separate conversion calculates lm or W under your supplied efficacy.

Illuminance Unit Converter

Convert the same illuminance between lux, kilolux and foot-candles, with metric units shown first.

Inputs and results
Inputs
A nonnegative illuminance and its unit: lx, klx or fc.
Results
The same illuminance in lx, klx and fc.

Daily Light Integral Planner

Calculate baseline DLI and the supplemental light time needed for your supplied target within a limited daily window.

Inputs and results
Inputs
Baseline DLI or representative PPFD/time periods, sourced target DLI, incremental supplement PPFD and available hours per day.
Results
Baseline, numerical dose gap, required and planned hours, achievable total and remaining gap.