Lighting Schedule Totals

Add counts, matching luminaire output and input power across groups, with separate lumen/lm-W and PPF/photon-efficacy quantities.

Add matching luminaire data across groups. The aggregate efficacy divides total output by total input power, rather than averaging the individual lm/W figures.

Results update as you edit.

Calculating needs JavaScript. The form becomes available when its script is ready; the guide below is always readable.

Calculation inputs

Calculation inputs
Keep photometric lumens and 400–700 nm photon flow separate. The same group arithmetic applies; no conversion is made between them.
One group per line; for example 4, 1000, 10. Use 1–100 rows, positive whole counts, nonnegative lm and positive W, without thousands separators.
Keep the operating setting and test basis consistent within each group. Do not mix lamp-only and luminaire output.

Continue your task

Keep group-level data as well as totals: different operating hours cannot be recovered from one combined wattage.

If this answers your question within the model’s limits, record the original inputs, unrounded result and conditions. Otherwise choose an action only when its condition applies:

See this task in the decision tree

Opening another tool does not transfer or store your entries. Keep the original values, units and conditions with the next calculation.

Keep each group’s light output and power together

A lighting schedule can contain different counts, lumen outputs and input powers. Summing one representative product from each row would lose the quantities. This calculator multiplies each group’s values by its count, then adds the groups:

Total lumens = Σ(count × initial complete-luminaire lm).

Total input watts = Σ(count × whole-luminaire input W).

YourHome’s lighting guidance distinguishes light output from input power and explains luminous efficacy in lm/W. Keep both values on the same complete-luminaire and operating-setting basis. Lamp-only output combined with power for a complete fitting can give a misleading efficacy. Required driver input belongs in the power figure.

The sum describes initial output from the luminaires. It does not describe the flux landing on a desk or the maintained illuminance of a room.

An artificial two-group schedule

Suppose one group contains four luminaires rated at 1,000 initial lm and 10 W each, and another contains two at 2,000 initial lm and 20 W each. The numbers are illustrative assumptions, not product recommendations.

Group Count Group output (lm) Group input (W)
First 4 4,000 40
Second 2 4,000 40
Total 6 8,000 80

The combined efficacy is 8,000 ÷ 80 = 100.00 lm/W. All totals use the entered decimals before display rounding. Count remains a whole number; lumens, watts and efficacy display to two decimal places.

Why the average of individual efficacies can be wrong

Imagine one 100 lm, 1 W light and one 900 lm, 3 W light. Their individual efficacies are 100 and 300 lm/W. Averaging those figures gives 200 lm/W, but the combined system produces 1,000 lm using 4 W: 250 lm/W. The larger power contribution must carry more weight. Dividing total output by total input does that directly.

Use the totals for the next task

The group counts and input watts can feed unadjusted lighting power density with a matching floor area. For energy and usage cost, each group also needs its operating hours and applicable tariff; one total wattage only represents all groups if their operating pattern is shared.

Do not divide total output by room area and treat the answer as actual illuminance. A declared-factor lumen-method estimate needs a compatible utilisation and maintenance model. Different luminaire types can have different distributions, so their flux totals do not establish one common UF or equivalent lighting service.

Compare photon output on a separate basis

For horticultural luminaires, select the PPF quantity and use 400–700 nm photosynthetic photon flux in µmol/s for each complete luminaire. DLC’s horticultural requirements distinguish total PPF from the quantity reaching a specific point, and define photon efficacy in µmol/J. Its North American qualification limits are not Australian requirements and are not applied here.

The group calculation remains Σ(count × PPF) and Σ(count × input W). Since one watt is one joule per second, total µmol/s divided by total J/s gives µmol/J. The result lists each group’s photon efficacy as well as the combined value, so two products can be compared by entering one in each row. Keep spectral band, operating setting and whole-system power boundaries compatible.

In an artificial comparison, one luminaire supplies 100 µmol/s at 50 W and another supplies 300 µmol/s at 100 W. Their individual photon efficacies are 2 and 3 µmol/J. Together they supply 400 µmol/s at 150 W = 2.67 µmol/J, rather than the simple average of 2.5. This comparison does not establish identical spatial distribution, spectrum or plant response. Actual receiving-plane PPFD still needs a measurement, a compatible optical model or an explicit photon delivery budget.

Related tools

Lighting Product Comparison

Compare two products and calculate luminaire efficacy, or convert lumens and input watts using a supplied matching efficacy.

Inputs and results
Inputs
Product specifications; conversion requires a supplied luminaire lm/W value, known lm or W and matching-data conditions.
Results
A side-by-side record and conditional lm/W; a separate conversion calculates lm or W under your supplied efficacy.

Lighting Energy and Running Cost

Estimate lighting kWh and usage cost with simple comparisons, mixed operating states, or different day types and seasonal schedules.

Inputs and results
Inputs
Counts, input W, non-overlapping state hours, specified days and optional usage rates; group IDs and mutually exclusive day-type counts where used.
Results
Energy in kWh and conditional usage cost in AUD; simple-mode A-minus-B differences or combined state/day-type totals.

Lighting Power Density

Calculate unadjusted whole-luminaire input power per floor area from groups of lights. No NCC compliance verdict.

Inputs and results
Inputs
Floor area in m² and groups with whole light counts and whole-luminaire input W.
Results
Total input watts and unadjusted W/m² for the declared boundary.

Browse all lighting tools