Measured Dimming Curve Interpolation

Estimate luminaire lm and input W separately within a supplied measured control-setting curve using piecewise linear interpolation.

Interpolate luminaire output and input power separately between your measured dimming points. A control percentage is not assumed to equal a percentage of light output or power.

Results update as you edit.

Calculating needs JavaScript. The form becomes available when its script is ready; the guide below is always readable.

Calculation inputs

Calculation inputs
2–100 comma-separated rows, strictly increasing settings from 0 to 100%. Use nonnegative values; positive lm requires positive W. Include standby watts if present at 0%.
Within the supplied measured setting range, not just within 0–100%.
All rows must describe the same system and measurement basis. Keep product, driver, control and test details with the curve.

Continue your task

Keep the estimated lm and W as a pair. A control percentage is not automatically the same percentage of output or input power.

If this answers your question within the model’s limits, record the original inputs, unrounded result and conditions. Otherwise choose an action only when its condition applies:

See this task in the decision tree

Opening another tool does not transfer or store your entries. Keep the original values, units and conditions with the next calculation.

A control setting is not a measured light fraction

A setting of 40% identifies a control command. It does not by itself establish 40% of full lumens or 40% of full input watts. The luminaire, driver and control system determine the response, and YourHome’s lighting guidance discusses dimming and product suitability. This tool uses supplied measurements for that same system rather than assuming a universal response curve.

Each row pairs a setting with complete-luminaire output in lm and matching electrical input in W. Keep the driver, protocol, operating conditions and measurement basis consistent. At a zero setting, enter measured standby power if the system still draws it; zero control command does not prove zero electrical input.

Interpolate output and input separately

For a setting x between two measured settings x₀ and x₁, let t = (x − x₀)/(x₁ − x₀). Apply linear interpolation to each quantity:

Lumens = (1 − t) × lm₀ + t × lm₁.

Watts = (1 − t) × W₀ + t × W₁.

Then divide the resulting lumens by watts to get lm/W when input power is positive. Interpolating endpoint efficacy instead would generally give a different answer because a ratio is not a linear sum. An exact supplied setting returns that measurement without interpolation.

Check an artificial midpoint

Take invented measurements of 200 lm at 3 W for setting 20%, and 800 lm at 8 W for setting 60%. At setting 40%, t = 20/40 = 0.5. The estimates are:

  • Output: (200 + 800)/2 = 500.00 lm.
  • Input: (3 + 8)/2 = 5.50 W.
  • Efficacy: 500/5.5 = 90.91 lm/W.

The midpoint of the endpoint efficacies would be about 83.33 lm/W, which is not the efficacy of the interpolated output and input. Results display to two decimal places, using unrounded values in the ratio.

Stay within the measured range

Rows must have strictly increasing control settings. Repeated settings need investigation rather than an arbitrary choice between conflicting measurements. Settings outside the measured endpoints are rejected even when they fall within 0–100%. The nearest measured interval is used inside the range; additional measurements can reveal curvature that a long straight segment misses.

Piecewise interpolation does not guarantee the system follows those straight lines. It also does not assess flicker, colour shift, minimum stable output, dimmer compatibility or electrical suitability. At zero input W and zero lm, efficacy is undefined; positive light with zero input is rejected for this electrically powered luminaire model.

Carry the estimated input watts and its operating setting into energy calculations only as the same conditional estimate. Keep separate durations for different settings, and use product comparison to retain the system details needed to interpret them.

Related tools

Lighting Product Comparison

Compare two products and calculate luminaire efficacy, or convert lumens and input watts using a supplied matching efficacy.

Inputs and results
Inputs
Product specifications; conversion requires a supplied luminaire lm/W value, known lm or W and matching-data conditions.
Results
A side-by-side record and conditional lm/W; a separate conversion calculates lm or W under your supplied efficacy.

Lighting Energy and Running Cost

Estimate lighting kWh and usage cost with simple comparisons, mixed operating states, or different day types and seasonal schedules.

Inputs and results
Inputs
Counts, input W, non-overlapping state hours, specified days and optional usage rates; group IDs and mutually exclusive day-type counts where used.
Results
Energy in kWh and conditional usage cost in AUD; simple-mode A-minus-B differences or combined state/day-type totals.

Lighting Schedule Totals

Add counts, matching luminaire output and input power across groups, with separate lumen/lm-W and PPF/photon-efficacy quantities.

Inputs and results
Inputs
One row per group: count, complete-luminaire lm or 400–700 nm PPF µmol/s, and whole-luminaire input W.
Results
Group count, output and input totals, with combined lm/W or µmol/J and individual photon group comparisons.

Browse all lighting tools