Pair the indoor reading with the same outdoor sky
A daylight factor expresses indoor daylight as a percentage of a simultaneous outdoor reference. In the daylight-factor definition, the indoor reading is on the working plane and the outdoor reference is on an unobstructed horizontal plane under an overcast sky. This tool evaluates that declared pair with artificial lighting off and direct sun excluded.
DF = indoor daylight illuminance ÷ outdoor illuminance × 100%.
Both readings use lx, so their units cancel. An outdoor value measured at a different time or behind an obstruction changes the denominator without necessarily describing the sky illuminating the room. A convenient outdoor reading is not automatically a valid reference.
Interpret the percentage against the actual readings
For an artificial pair of 200 lx indoors and 10,000 lx outdoors, DF = 200/10,000 × 100 = 2.00%. This is a ratio for the stated point and conditions, rather than a recommended value or a verdict about the room.
- If both readings double together, the ratio stays 2.00%.
- If the indoor reading is 100 lx while the outdoor reference remains 10,000 lx, the ratio is 1.00%.
- Zero indoor daylight gives 0.00%. A zero outdoor reference makes the ratio undefined and is rejected.
The display uses two decimal places; a positive ratio below 0.01% is marked below display precision. Display rounding does not alter the underlying comparison with the outdoor reference.
A value above 100% needs a condition check
The calculator retains a mathematically valid ratio above 100% and flags it for review. Check whether artificial light or direct sun entered the indoor reading, the outdoor sensor was shaded, the readings were simultaneous, the ranges and units matched, and the instruments were appropriate. The warning does not identify which condition caused the result or certify a corrected reading.
One pair of readings does not describe every location or the entire year. Seasonal sun positions, weather, shading, room surfaces and window conditions can change actual daylight. A daylight factor is also separate from glare, heat gain, electric-light savings and annual climate-based daylight measures. This calculator supplies no Australian target, standard clause or pass/fail classification.
Use illuminance conversion when instruments report different units, preserving the measurement conditions. Meter specification range can interpret a compatible single-reading specification; it does not combine the uncertainty of this two-reading ratio. For several points, retain their individual readings and representative areas before using sample statistics.