Room Index and Working-plane Geometry

Calculate rectangular area, luminaire-to-plane height and room index from dimensions measured on a common basis.

Prepare rectangular dimensions for a supplied lighting method. The two heights must use the same level datum; the result does not select a utilisation factor.

Results update as you edit.

Calculating needs JavaScript. The form becomes available when its script is ready; the guide below is always readable.

Calculation inputs

Calculation inputs
Positive inside length of the rectangular space.
Positive inside width, perpendicular to length.
Height above the level datum used for the working plane; use the applicable optical reference, not automatically the ceiling.
Zero or more, below the luminaire reference, measured from the same level datum.
Do not subtract heights measured from different floors or reference levels.

Continue your task

Carry unrounded area and height; use K only with a compatible utilisation-factor method, not as a lookup that chooses UF by itself.

If this answers your question within the model’s limits, record the original inputs, unrounded result and conditions. Otherwise choose an action only when its condition applies:

See this task in the decision tree

Opening another tool does not transfer or store your entries. Keep the original values, units and conditions with the next calculation.

Use the height above the working plane

Room index describes the proportions of a rectangular space for a specified lighting method. It uses the separation between the luminaire reference and the working plane, rather than automatically using ceiling height. The NATSPEC lumen-method TECHnote, page 1, explains this geometry and its role in consulting utilisation data.

Let L and W be inside length and width in metres. If the source reference is at height H and the working plane at height P above the same level datum, their separation is h = H − P. The rectangular area is A = L × W, and:

Room index K = L × W ÷ [h × (L + W)].

K has no unit: both numerator and denominator have units of square metres. A larger K generally means a wider space relative to its source-to-plane height. It is not itself a percentage of light reaching the plane.

A common datum matters

Subtracting a source height measured from one floor level from a bench height measured from another gives the wrong separation. Suspended luminaires can also sit below the ceiling. Use the optical reference required by the applicable data, and identify the plane where the calculation is intended to apply.

Check an artificial rectangular example

Take a 10 m by 5 m room, with the luminaire reference 3 m and the working plane 1 m above a common datum. These are invented dimensions, not recommended installation heights.

  • Area: 10 × 5 = 50.00 m².
  • Source-to-plane separation: 3 − 1 = 2.00 m.
  • Room index: 50 ÷ [2 × (10 + 5)] = 5/3, displayed as 1.6667.

Increasing both reference heights by the same amount leaves the separation and K unchanged. Doubling h while keeping length and width fixed halves K. The display rounds area and height to two decimal places and K to four; display rounding is not used in later calculations.

Room index does not choose a utilisation factor

A manufacturer table may need room index together with the applicable luminaire distribution and surface reflectances. Tables can use different flux and cavity conventions. A K value from this tool does not make a table appropriate, and interpolating or rounding into a table must follow that table’s method.

The lumen-method estimate requires an explicitly supplied UF and maintenance basis. Maintenance-factor composition separately combines declared maintenance components. For a coordinate sketch, equal-cell grid geometry uses the rectangle without claiming that its point spacing gives suitable lighting.

Related tools

Maintenance Factor Composition

Multiply four supplied maintenance components on a matching basis without choosing product data or a cleaning schedule.

Inputs and results
Inputs
LLMF, LSF, LMF and RSMF fractions, plus their common source, period and maintenance basis.
Results
Combined maintenance factor and modelled percentage reduction from the initial level.

Rectangular Lighting Grid Geometry

Calculate an equal-cell grid, axis coordinates and spacing-to-height ratios. Geometry supplies no lighting adequacy verdict.

Inputs and results
Inputs
Rectangle length and width in m, rows, columns and positive height above the working plane in m.
Results
Point count, centres along each axis, adjacent spacing and conditional spacing-to-height ratios.

Lumen Method Estimate

Estimate average maintained illuminance with declared UF/MF, or use a separate supplied photon-delivery budget for average PPFD and count.

Inputs and results
Inputs
Working-plane area in m², initial whole-luminaire lm, UF/MF fractions, count or target lx, and recorded assumptions.
Results
Conditional average maintained lx, or a rounded-up luminaire count and its modelled average.

Browse all lighting tools