Exposure and ND Calculator

Solve shutter time, aperture or ISO after an ND change, and convert cine frame rate and shutter angle to exposure time.

Keep nominal continuous-light exposure equivalent when changing aperture, ISO or an ideal neutral-density filter stack. The separate cine task converts frame rate and shutter angle to time.

Results update as you edit.

Calculating needs JavaScript. The form becomes available when its script is ready; the guide below is always readable.

Calculation inputs

Calculation inputs
The remaining target settings are held fixed; inactive fields are ignored.
Greater than zero; enter 8 for f/8, not the physical aperture diameter.
Greater than zero, on the same sensitivity basis as the target.
Choose seconds or a frame-rate/angle pair. Use a decimal second value, such as 0.0078125 for 1/128 s.
Positive decimal seconds. Fraction notation such as 1/128 is not accepted.
Positive frames per second; the time is angle divided by 360 times this rate.
Greater than zero and no more than 360°. This is a time model, not a rolling-shutter or flicker assessment.
Each entry describes absolute loss; select one expression for the entire comma-separated stack.
Stops/OD: zero or more; transmission: greater than 0% and no more than 100%. Commas stack up to 20 filters. No filter is explicitly 0 stops, 0 OD or 100% transmission.
Absolute target loss, including filters retained from the baseline. The tool subtracts baseline loss once.
Use the selected expression for each comma-separated filter. Removing a filter is a smaller absolute target loss, rather than a negative filter value.
Greater than zero. Ignored when aperture is the setting being calculated.
Greater than zero. Ignored when ISO is the setting being calculated.
Positive decimal seconds. Ignored when shutter time is the setting being calculated.

Continue your task

Keep the solved setting with its ND and ISO basis. Setting EV differs from the unfiltered-scene equivalent EV100.

If this answers your question within the model’s limits, record the original inputs, unrounded result and conditions. Otherwise choose an action only when its condition applies:

See this task in the decision tree

Opening another tool does not transfer or store your entries. Keep the original values, units and conditions with the next calculation.

What stays equivalent when an ND filter changes?

A neutral-density filter reduces the light reaching the sensor. Under a steady scene and an ideal neutral filter, keeping the same aperture and ISO therefore requires a longer exposure. A loss of three stops transmits one eighth of the light, so exposure time must increase eightfold. Removing that same filter reverses the adjustment.

The calculation compares the absolute baseline stack with the absolute target stack. If a two-stop filter stays in place and a further one-stop filter is added, enter two stops at baseline and three stops at target. Entering only the new one-stop filter as the target would instead describe a reduction in total attenuation.

For f-number N, time t in seconds, ISO S and absolute ND loss k in stops, the equivalent-time relationship is:

t₂ = t₁ × (N₂/N₁)² × (S₁/S₂) × 2^(k₂ − k₁).

The squared aperture ratio follows the area change associated with f-number. Doubling the f-number requires four times as much time when the other inputs stay fixed. Doubling ISO halves the required time in this nominal setting model. Nikon’s exposure-mode explanation illustrates the relationship between shutter time and aperture; the tool also solves the equation for aperture or ISO when time is held fixed.

Setting EV and scene-equivalent EV answer different questions

Setting EV is log₂(N²/t). Normalising that setting to ISO 100 subtracts log₂(S/100). These are camera-setting descriptions; adding the filter loss gives the unfiltered-scene equivalent EV100 within the same ideal exposure model.

In an artificial example, f/8, 1/128 s and ISO 100 without a filter give setting EV100 = 13. Adding three stops of ND changes the equivalent time to 1/16 s, giving setting EV100 = 10. Adding the three-stop attenuation back gives scene-equivalent EV100 = 13. The scene has not become three stops darker simply because a filter was placed in front of the lens.

Neither figure is converted to lux here. A lux-to-camera-exposure relationship needs an identified incident-meter calibration and measurement basis; reflected-light metering also depends on what is being measured. An EV display alone does not supply those missing conditions.

Stops, optical density and transmission

For fractional transmission T, the loss is −log₂(T) stops, while optical density is −log₁₀(T). Ideal stacked transmissions multiply, so their stop losses and optical densities add.

Ideal filter description Exact relationship
3 stops 12.5% transmission; OD approximately 0.903089987
OD 0.3 Approximately 0.996578 stop; not mathematically exactly one stop
50% followed by 25% transmission 12.5% combined transmission; 3 stops

Manufacturer labels may round these relationships. LEE’s filter records illustrate the product-specific context of filter data. Real spectral transmission, reflections, lens T-stop differences and filter tolerances are not recovered from a nominal ND number.

Frame rate and shutter angle describe the exposure window

The cine relationship is t = angle ÷ (360 × frames per second). At 25 frames/s and 180°, the time is 0.020 s, or 1/50 s. Sekonic’s L-308X-U specifications identify cine frame-rate and shutter-angle measurement modes. The angle is not a claim that every camera implements the same readout behaviour.

Exposure time is shown with significant digits, with a reciprocal expression for times no longer than one second. Very short times are not rounded to 0.00 s. Calculated f-numbers and ISO values remain arithmetic values rather than recommendations for the nearest available camera dial position. Film reciprocity failure, flash synchronisation, moving-subject blur and light-source banding require separate consideration. For manual flash exposure from a matched manufacturer rating, use the Flash Guide Number Calculator.

Related tools

Point-source Illuminance

Estimate direct point illuminance from directional candela, add compatible sources, or scale a measured direct contribution by distance.

Inputs and results
Inputs
Directional intensity in cd, source-to-point distance in m and incidence angle from the normal in degrees.
Results
Direct illuminance in lx at the specified point, with model conditions.

Flash Guide Number Calculator

Use matching metric GN ratings to solve aperture, distance or required energy fraction, including compatible same-point flash contributions.

Inputs and results
Inputs
Full-power reference GN and ISO, shooting ISO, manual energy fraction, flash-to-subject distance or f-number and rating conditions.
Results
Nominal aperture, distance, effective GN or required energy fraction, with an explicit over-full-power result when applicable.

Lighting Ratio Calculator

Calculate key/fill or bright/dark ratios and stop differences from compatible readings, with a separate flash/ambient share mode.

Inputs and results
Inputs
Two comparable linear readings or same-ISO/shutter metered f-numbers, measurement definition and conditions.
Results
Named light ratio, stop difference, optional declared equal-fill bright/dark model or flash exposure share.

Browse all lighting tools