Lighting Ratio Calculator

Calculate key/fill or bright/dark ratios and stop differences from compatible readings, with a separate flash/ambient share mode.

Compare separately metered key/fill contributions, direct bright/dark totals, or compatible flash/ambient exposure contributions. The measurement definition determines what the ratio means.

Results update as you edit.

Calculating needs JavaScript. The form becomes available when its script is ready; the guide below is always readable.

Calculation inputs

Calculation inputs
Key/fill means each light measured separately. Bright/dark uses measured totals directly. Flash/ambient uses matched exposure contributions.
A metered f-number is squared before forming a light ratio; linear readings are used directly.
Nonnegative linear reading, or positive metered f-number, according to the selected basis. For bright/dark mode the first reading must be at least the second.
Same measurement units and basis as the first. Zero linear readings are retained as zero; a zero denominator does not become a finite ratio.
This explicit model gives bright:dark = (key + fill):fill. It is not applied to readings that already contain total light.
Identify the quantity and comparable measurement procedure; for flash/ambient include the common exposure window.
Flash and ambient contributions must share an integrated exposure window. Separate measurements must remain comparable.

Continue your task

Keep the measurement definition with the ratio and stops; the additive equal-fill model is an explicit assumption.

If this answers your question within the model’s limits, record the original inputs, unrounded result and conditions. Otherwise choose an action only when its condition applies:

See this task in the decision tree

Opening another tool does not transfer or store your entries. Keep the original values, units and conditions with the next calculation.

“Four to one” needs a measurement definition

A key-to-fill contribution ratio and a bright-to-dark total ratio can have different values for the same setup. The distinction starts with what was measured: each light separately, or the total light on two sides of a subject.

With separate compatible readings K for key-only and F for fill-only, the contribution ratio is K/F. Only under the additional model that fill reaches both sides equally and key adds solely to the bright side does the bright-to-dark ratio become (K + F)/F. The extra one is a consequence of that declared fill contribution, rather than an adjustment that belongs to every ratio.

If the readings already describe bright-side total and dark-side total, divide them directly. Adding one again would count light that is already included.

Metered f-numbers must be squared

At the same ISO and shutter time, nominal metered f-number squared is proportional to the compatible exposure quantity. Two readings of f/8 and f/4 therefore correspond to 64/16 = 4:1, rather than 2:1. The signed first-to-second stop difference is log₂(ratio).

Artificial measurement at fixed ISO and shutter Named ratio Stop difference
Key-only f/8; fill-only f/4 Key:fill = 4:1 2.00 stops
Same separate readings, with equal fill on both sides and key only on the bright side Modelled bright:dark = 5:1 Approximately 2.32 stops
Bright total f/8; dark total f/4 Measured bright:dark = 4:1 2.00 stops

This squared relationship is also why compatible flash exposure contributions are added as squared f-numbers in the Flash Guide Number Calculator. Scantips’ direct-flash discussion supplies the corresponding guide-number and exposure context. A display’s electrical-power percentage is a different quantity and does not establish light at the subject.

Flash share needs a common exposure window

Flash and ambient contributions can be compared when they describe compatible light exposure integrated over the same camera exposure window and receiver basis. For example, artificial linear contributions of 3 units from flash and 1 unit from ambient give a flash-to-ambient ratio of 3:1 and a flash share of 3/(3 + 1) = 75%.

Instantaneous ambient illuminance in lux cannot be divided by an unmatched flash exposure reading to obtain that share. Changing shutter time can change the ambient contribution, so keep the chosen exposure window in the measurement record. Sekonic’s meter specifications distinguish ambient and flash measurement tasks; their existence does not make every pair of readings comparable.

Zero readings and measurement geometry

A genuine zero linear contribution remains zero. If the second contribution is zero, there is no finite first-to-second ratio or logarithmic stop difference. If both flash and ambient are zero, the flash share is undefined rather than 0%. A zero f-number is not a valid metered aperture and is rejected.

Keep receiver position, orientation, measurement quantity and operating conditions comparable. The bright/dark option requires the bright reading to be at least the dark reading so that the labels retain their meaning. These ratios describe the supplied measurements and explicit fill model; they do not predict skin-reflection pixel values or choose a preferred artistic lighting style.

Related tools

Exposure and ND Calculator

Solve shutter time, aperture or ISO after an ND change, and convert cine frame rate and shutter angle to exposure time.

Inputs and results
Inputs
Baseline and target camera settings, absolute ND losses or transmission stacks; optional cine fps and angle.
Results
Equivalent settings, ND transmission/density, setting EV and distinctly labelled unfiltered-scene equivalent EV100.

Flash Guide Number Calculator

Use matching metric GN ratings to solve aperture, distance or required energy fraction, including compatible same-point flash contributions.

Inputs and results
Inputs
Full-power reference GN and ISO, shooting ISO, manual energy fraction, flash-to-subject distance or f-number and rating conditions.
Results
Nominal aperture, distance, effective GN or required energy fraction, with an explicit over-full-power result when applicable.

Browse all lighting tools