Find intensity in a particular direction
An IES photometric file records how luminous intensity varies with direction. That is useful when a calculation needs candela towards a particular point, rather than total lumens from a luminaire. Two lights with the same lumens can have different directional intensities because they distribute their output differently.
This lookup reads a declared subset of LM-63-2002 Type C files: TILT=NONE, with both ballast fields equal to 1. Choose a local file or paste its complete text; processing stays in your browser. Other versions, Type A or B photometry, TILT corrections and non-unity ballast fields need an application that supports those cases.
The LM-63 field description places the vertical angles first, then horizontal planes, followed by one block of candela samples for each horizontal plane. The explicit candela multiplier applies once to those samples. The result keeps file identity, requested direction and interpolation method together.
Read the coordinates before using the number
The horizontal C angle identifies a photometric plane; the vertical gamma angle identifies a direction in that plane. In this Type C representation, gamma 0° is downward along the luminaire’s photometric axis, 90° is horizontal and 180° is upward. These coordinates belong to the photometric file. They do not automatically identify north in a room or the tilt of an installed fitting.
Before carrying a value into the point-source illuminance estimate, establish how the installed luminaire is oriented and which file direction points towards the receiver. The receiver’s incidence angle is a separate angle measured from its surface normal. Entering the file’s gamma angle as the incidence angle generally describes a different geometry.
Use data for the exact product, optic, operating setting and test basis. A similarly named file may describe a different lens or dimming state.
Interpolate only inside the recorded grid
At a recorded horizontal and vertical angle, the result is the stored sample multiplied by the file multiplier. Between angles, the lookup linearly interpolates in gamma in each neighbouring C plane, then between those two planes. This is an approximation between samples, rather than another measurement.
The artificial example contains these unscaled values:
At gamma 22.5°, the halfway values are 80 in C 0° and 60 in C 90°. At C 45°, their halfway value is 70. With the multiplier of 2, the result is 140 cd. At the recorded C 0° / gamma 45° point, the result is 60 × 2 = 120 cd. These invented values illustrate the method; they are not product ratings.
The curve and table show recorded vertical samples in a selected horizontal plane, after applying the multiplier. The plotted line joins those samples. Its axes are intensity and gamma angle; it is not a polar plot or a floor illuminance map. The largest stored sample is useful for inspecting the grid, but a sparse grid can miss a higher intensity between measurements.
A missing direction is unavailable here
Many legitimate IES files store only part of a distribution and rely on symmetry rules. This lookup limits queries to the angle rectangle actually stored in the file. It does not reflect quadrants, infer rotational symmetry, map 360° onto 0°, or fill an omitted hemisphere with zeros.
A file with C planes from 0° to 90° can be queried within that range. C 180° is unavailable here even if another application could expand the file using an applicable symmetry rule. A single-plane file permits queries only at that recorded C angle. Use a fuller photometric application when the required direction needs expansion.
Keep candela, lamp lumens and watts separate
The file may use positive reference lamp lumens, or −1 to identify absolute photometry. As Lighting Analysts explains, a relative file can use a test-lumen basis such as 1,000 rather than a current product’s advertised lumens. The lookup reports that field without using it to rescale the candela grid. It does not multiply the grid by the lamp count a second time.
Reported input watts and dimension units remain file metadata. Neither supplies missing directional output. Total luminaire lumens require an appropriate integration of the distribution, with its coverage and conventions understood; they cannot be read directly from a lamp-reference field. This tool does not calculate total flux or lm/W.
If samples at gamma 0° or 180° differ between planes, a warning identifies the inconsistency because they describe the same physical direction. Original values remain visible. The lookup does not average, repair or choose a preferred pole value; check the source file before relying on that direction.
What the lookup can support next
A matching directional candela value can be one input to a conditional direct point-source calculation. It does not by itself establish surface illuminance, uniformity, glare, maintained output or Australian compliance. Nearby large luminaires, obstructions and reflected light may require a different model.
For an idealised constant-intensity cone without a real file, use Uniform Cone Flux. Its constant-candela assumption should not replace the varying samples in an actual IES file.