LED Strip Cut-length Planner

Plan repeated identical LED strip lengths from a supplied cut interval, choosing not to exceed or to reach a target, with optional matching per-metre totals.

Choose a length made from whole manufacturer-permitted cut intervals, repeated across identical runs. The editable example is artificial; verify the actual product’s cut marks and limits.

Results update as you edit.

Calculating needs JavaScript. The form becomes available when its script is ready; the guide below is always readable.

Calculation inputs

Calculation inputs
A finite length greater than zero. Measure the intended strip length; allow separately for connectors, end caps and installation clearances.
A finite interval greater than zero for this exact strip, repeated from a manufacturer-permitted starting point. Use marked cut positions; do not infer the interval from LED spacing.
Choose the longest allowed length not exceeding the target, or the shortest allowed length reaching it. Reaching may exceed the available space.
A positive whole number. Every run uses the same target and interval; different run lengths need separate calculations. Total intervals must remain within the safe integer range.
Zero or more on a stated product, setting and output boundary. Blank omits lumens. Strip output is not automatically the output of a fitted diffuser or complete luminaire.
Zero or more on the same strip and stated operating setting. Blank omits watts. A maximum rating is not measured operating power; driver and control losses are not inferred.
Positive manufacturer density on the same counting basis throughout the strip, giving a whole LED count in each permitted cut section. Blank omits counts. This does not predict visible dots or brightness.
Record the exact strip/model, cut-interval source, permitted starting point and any ratings’ setting and measurement boundary. Also check the manufacturer’s maximum run length and installation instructions.

Continue your task

Choose a length below or above the target and retain the per-run shortfall or excess. Optional strip totals do not include inferred driver losses, connectors or fitted diffuser losses.

If this answers your question within the model’s limits, record the original inputs, unrounded result and conditions. Otherwise choose an action only when its condition applies:

See this task in the decision tree

Opening another tool does not transfer or store your entries. Keep the original values, units and conditions with the next calculation.

A target length may fall between permitted cuts

A measured 4.37 m space does not mean a strip can be cut to exactly 4.37 m. The permitted cut marks belong to the particular product. For example, ENTTEC’s 12V RGB long-range pixel strip specifies 50 mm spacing between cuttable sections. That is one product’s interval, not a general rule for LED strips, and the LED spacing itself is not a substitute for the cut specification.

This calculation treats a run as a whole number of identical permitted length increments, measured from a permitted starting point. It answers a length question before installation allowances: connectors, end caps, cable entries and clearances must be considered separately. Always retain the manufacturer’s maximum run length and installation conditions alongside the length plan.

Choose which side of the target matters

Let T be the target length in m and c the manufacturer’s cut interval in mm. Convert the interval to metres as δ = c/1,000, using the exact relationship 1 mm = 0.001 m.

  • Do not exceed the target: n = floor(T/δ). This gives the greatest whole number of intervals that fits within T.
  • At least reach the target: n = ceil(T/δ). This gives the smallest whole number of intervals whose length reaches T; it can be too long for a confined space.

The actual strip length per run is L = nδ. Shortfall is T − L in the first mode; excess is L − T in the second. The other difference is zero. A smaller cut interval gives finer length choices, but selecting a different interval requires a product that actually permits it.

The interval count is not the number of cutting operations. A length made from 87 intervals might be separated from a larger reel at one marked cut; this planner does not work out how to allocate stock reels, leftovers or joining positions.

Compare two choices for an artificial 4.37 m target

For this invented example, assume a repeating 50 mm interval from a permitted origin, one run, 1,000 lm/m and 10 W/m on a common strip basis. These example values describe no real product.

T/δ = 4.37/0.05 = 87.4. The two length choices are:

Requirement Intervals per run Actual length Difference from target Conditional strip lm Conditional strip W
Do not exceed 87 4.35 m 0.02 m shortfall 4,350 lm 43.5 W
At least reach 88 4.4 m 0.03 m excess 4,400 lm 44 W

The shorter option leaves 20 mm; the longer option extends 30 mm beyond the target. Neither resolves whether connectors and clearances fit. At a target of exactly 4.35 m, both modes give 87 intervals and zero difference. The calculation chooses the interval count using the original decimal entries, without rounding the length first. Results preserve exact finite-decimal values rather than rounding a shortfall away; that arithmetic precision does not imply the same measurement or manufacturing precision.

If the target is only 30 mm with a 50 mm interval, the “do not exceed” option gives zero intervals and a 30 mm shortfall. It means no complete interval fits. It does not describe an installable zero-length product. The “at least reach” option gives one 50 mm interval with 20 mm excess.

Repeat the chosen length, not the requested length

For r identical runs, total strip length = rL. Three runs of the shorter artificial choice use 3 × 4.35 = 13.05 m, containing 261 cut intervals. Each run still has its own 0.02 m shortfall. Multiplying the requested 4.37 m by three would overstate the actual cut-strip total.

If you also supply a matching manufacturer LED density d in LEDs/m, the repeated section must contain a whole number dδ of LEDs. An artificial 60 LEDs/m with a 50 mm interval gives 3 LEDs per section, 261 per 4.35 m run, and 783 across three runs. Counts use the actual cut length. A density of 61 LEDs/m with that interval would give 3.05 per section and is rejected as inconsistent with this repeated-section model. Keep the product’s counting basis consistent: packages, individual emitters and addressable pixels can describe different things. Density alone does not predict brightness or visible dots through a diffuser.

Different run targets need separate calculations. A combined total of 13.05 m is a length account, not a purchase quantity: stock reel sizes, usable leftovers, maximum connected lengths and permitted joining methods can affect what must be ordered.

Per-metre totals keep their original rating boundary

When a matching value is supplied, total lm = total cut length × lm/m and total W = total cut length × W/m. In the three-run artificial example, these give 13,050 lm and 130.5 W. Either per-metre value can be omitted independently; blank does not mean zero.

Keep the product, setting and measurement boundary with each rating. A maximum W/m rating produces a total on that maximum-rating basis, rather than a measurement of everyday consumption. Strip-output lm/m does not automatically include losses in a fitted diffuser or describe the complete luminaire’s delivered output. Multiplying lm/m by length also does not establish work-surface lux.

The strip-power total is not a power-supply recommendation. Power-supply suitability, controls, permissible run lengths, voltage drop, wiring and circuit selection need the actual system information and applicable installation method. For energy and running cost, first establish the finished system’s input watts, including the required driver and control input; do not silently reuse strip watts as mains input. Keep the resulting operating states and hours with that later estimate.

Related tools

Lighting Product Comparison

Compare two products and calculate luminaire efficacy, or convert lumens and input watts using a supplied matching efficacy.

Inputs and results
Inputs
Product specifications; conversion requires a supplied luminaire lm/W value, known lm or W and matching-data conditions.
Results
A side-by-side record and conditional lm/W; a separate conversion calculates lm or W under your supplied efficacy.

Lighting Energy and Running Cost

Estimate lighting kWh and usage cost with simple comparisons, mixed operating states, or different day types and seasonal schedules.

Inputs and results
Inputs
Counts, input W, non-overlapping state hours, specified days and optional usage rates; group IDs and mutually exclusive day-type counts where used.
Results
Energy in kWh and conditional usage cost in AUD; simple-mode A-minus-B differences or combined state/day-type totals.

Browse all lighting tools