How much does it cost to leave lights on overnight?
Estimate one night or several nights of lighting usage cost from the actual watts, operating hours and usage rate, without counting midnight twice.
The cost depends on how many lights stay on, their input watts, the hours they operate and your electricity usage rate. For an invented example, four 9 W lights running for eight hours at 30 c/kWh use 0.288 kWh and cost AUD0.0864 for one night, displayed as 0.29 kWh and AUD0.09. Those inputs are an illustration, not a typical Australian tariff or a claim about your lights.
Use the Lighting Energy and Running Cost calculator for your own numbers. It estimates the lights’ usage cost, rather than the whole electricity bill. Start by replacing its example inputs or selecting Clear all.
How many hours does one overnight period contain?
Count the time the lights are actually on. From 10 pm to 6 am the following morning is two hours before midnight plus six after it: eight hours in total. Crossing midnight does not turn that one overnight period into two eight-hour uses.
In the calculator’s simple mode, enter 8 in Operating hours per day and 1 in Specified period (days) for one such night. Here the one-day model contains one eight-hour use; it does not attempt to assign the electricity to calendar dates. For 30 identical nights, use 8 hours per day and 30 days. This represents 30 repetitions of the same use, not every hour in a calendar month.
If the lights turn off during the night, add only their on-time. If clocks change during a daylight-saving transition, use the actual elapsed operating time rather than assuming the usual clock-time difference. Simple mode repeats one duration each day. For unequal nightly schedules, use the day-type mode to record mutually exclusive types of day and how many of each occur in the specified period.
Which watts and electricity price should you enter?
Use the electrical input power at the setting being modelled. For an integrated fitting, that means the complete luminaire’s input, including its required driver. A product’s lumen output or an “equivalent wattage” comparison is not its operating input power. YourHome’s lighting guidance explains why watts and light output are different quantities.
YourHome is © Commonwealth of Australia, 2026, licensed under CC BY 4.0, subject to its copyright exceptions. The explanation here is paraphrased; its images and product tables are not reproduced.
Enter the number of identical lights that follow this schedule. If some lights have different watts or operating hours, use separate groups in mixed-state or day-type mode. Do not average their nameplate values and assume the result describes every night. For a smart light’s standby consumption, enter its supplied standby input W and hours as a separate, nonoverlapping state of the same physical group. The calculator does not infer standby power from the on-state rating.
For the price, find the electricity usage charge, with its unit, on your plan or bill. Victorian Energy Compare’s bill guide distinguishes usage charges in cents per kWh from the separate daily supply charge. It also explains that the amount due can include other balances. Dividing the total amount due by the bill’s kWh therefore does not reliably give the usage rate needed here.
Is 30 c/kWh the same as AUD0.30/kWh?
Yes: 30 ÷ 100 = AUD0.30 per kWh. Choose the corresponding rate unit before entering your price. The calculator converts an existing valid rate when you switch units, preserving the same price. A value of 30 entered as AUD/kWh would be one hundred times the price of 30 c/kWh.
Keep the tax basis consistent with the cost you want to estimate. If the rate is unknown, leave it blank: the calculator can still show energy, but it cannot supply a price for you.
What does the worked example look like in the calculator?
The example below assumes four identical lights, constant 9 W input while on, eight hours each night and one constant rate of 30 c/kWh. It excludes other electricity charges. Every number is an artificial assumption.
| Calculator input | One night | Thirty identical nights |
|---|---|---|
| Number of lights | 4 | 4 |
| Input power per light | 9 W | 9 W |
| Operating hours per day | 8 h/day | 8 h/day |
| Specified period | 1 day | 30 days |
| Usage rate and unit | 30 c/kWh | 30 c/kWh |
For one night, total input power is 4 × 9 = 36 W. Operating for eight hours uses 36 × 8 = 288 Wh, or 288 ÷ 1000 = 0.288 kWh. Multiplying by the rate gives 0.288 × AUD0.30 = AUD0.0864.
This power-times-duration relationship follows the U.S. Energy Information Administration’s explanation of watt-hours and kilowatt-hours. The unit relationship is used here; Australian billing prices and the example assumptions do not come from that source.
For 30 identical nights, energy is 0.288 × 30 = 8.64 kWh, and usage cost is 8.64 × AUD0.30 = AUD2.592.
| Result | One night | Thirty identical nights |
|---|---|---|
| Unrounded energy | 0.288 kWh | 8.64 kWh |
| Displayed energy | 0.29 kWh | 8.64 kWh |
| Unrounded usage cost | AUD0.0864 | AUD2.592 |
| Displayed usage cost | AUD0.09 | AUD2.59 |
Energy displays to two decimal places; cost displays to the nearest cent, with exact half-cents rounded away from zero. Keep the unrounded energy and cost until the final display. Multiplying the displayed nightly cost, AUD0.09, by 30 would give AUD2.70, which is not the unrounded calculation’s AUD2.59 result. The methodology explains this display rule.
What if your overnight rate changes partway through?
An overnight schedule may cross more than one time-of-use rate. Use the prices and times in your own plan: “overnight” does not itself identify a single tariff. Simple mode accepts one constant usage rate per scenario. For a split-price night, select mixed-state mode and enter each nonoverlapping interval with its duration and applicable AUD/kWh rate. Entering only the cheapest rate would misprice hours charged at another rate.
The calculator adds the entered intervals’ unrounded energy and costs before display rounding. It does not automatically split a schedule, import a plan or calculate demand charges. If you cannot establish the applicable rates, use it for the lighting’s energy quantity and leave cost unavailable.
The result answers what the entered operating pattern costs at the entered usage rate. It does not establish whether leaving lights on is necessary, whether an alternative provides equivalent lighting, or what your complete bill will be.